Inhaled Nitric Oxide as a Preoperative Test (INOP Test I)

Author:

Balzer David T.1,Kort Henry W.1,Day Ronald W.1,Corneli Howard M.1,Kovalchin John P.1,Cannon Bryan C.1,Kaine Stephen F.1,Ivy D. Dunbar1,Webber Steven A.1,Rothman Abraham1,Ross Robert D.1,Aggarwal Sanjeev1,Takahashi Masato1,Waldman J. Deane1

Affiliation:

1. From the St. Louis Children’s Hospital, St. Louis, Mo. (D.T.B., H.W.K.); Primary Children’s Medical Center, Salt Lake City, Utah (R.W.D., H.M.C.); Texas Children’s Hospital, Houston, Tex. (J.P.K., B.C.C.); Children’s Mercy Hospital, Kansas City, Mo. (S.F.K.); Children’s Hospital of Denver, Denver, Colo. (D.D.I.); Children’s Hospital of Pittsburgh, Pittsburgh, Pa. (S.A.W.); University of California, San Diego, San Diego, Calif. (A.R.); Children’s Hospital of Michigan, Detroit, Mich. (R.D.R., S.A.);...

Abstract

Background This study was performed to determine whether a preoperative hemodynamic evaluation with oxygen and inhaled nitric oxide identifies patients with pulmonary hypertension who are appropriate candidates for corrective cardiac surgery or transplantation more accurately than an evaluation with oxygen alone. Methods and Results At 10 institutions, 124 patients with heart disease and severe pulmonary hypertension underwent cardiac catheterization to determine operability. The ratio of pulmonary and systemic vascular resistance (Rp:Rs) was determined at baseline while breathing ∼21% to 30% oxygen, and in ∼100% oxygen and ∼100% oxygen with 10 to 80 parts per million nitric oxide to evaluate pulmonary vascular reactivity. Surgery was performed in 74 patients. Twelve patients died or developed right heart failure secondary to pulmonary hypertension following surgery. Rp:Rs<0.33 and a 20% decrease in Rp:Rs from baseline were chosen as 2 criteria for operability to determine, in retrospect, the efficacy of preoperative testing in patient selection. In comparison to an evaluation with oxygen alone, sensitivity (64% versus 97%) and accuracy (68% versus 90%) were increased by an evaluation with oxygen and nitric oxide when Rp:Rs<0.33 was used as the criterion for operability. Specificity was only 8% when a 20% decrease in Rp:Rs from baseline was used as the criterion for operability. Conclusion By using a combination of oxygen and inhaled nitric oxide, a greater number of appropriate candidates for corrective cardiac surgery or transplantation can be identified during preoperative testing when a specific value of Rp:Rs is used as a criterion for operability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 115 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3