TAXUS I

Author:

Grube Eberhard1,Silber Sigmund1,Hauptmann Karl Eugen1,Mueller Ralf1,Buellesfeld Lutz1,Gerckens Ulrich1,Russell Mary E.1

Affiliation:

1. From the Heart Center Siegburg (E.G., R.M., L.B., U.G.), Siegburg, Germany; Klinik Dr. Mueller (S.S.), Muenchen, Germany; Krankenhaus der Barmherzigen Brüder (K.E.H.), Trier, Germany; and Boston Scientific Corp (M.E.R.), Natick, Mass.

Abstract

Background— The TAXUS NIRx stent (Boston Scientific Corp) provides local delivery of paclitaxel via a slow-release polymer coating. The TAXUS I trial was the first in-human experience evaluating safety and feasibility of the TAXUS NIRx stent system compared with bare NIR stents (control) (Boston Scientific Corp) for treatment of coronary lesions. Methods and Results— The TAXUS I trial was a prospective, double-blind, three-center study randomizing 61 patients with de novo or restenotic lesions (≤12 mm) to receive a TAXUS (n=31) versus control (n=30) stent (diameter 3.0 or 3.5 mm). Demographics, lesion characteristics, clinical outcomes were comparable between the groups. The 30-day major adverse cardiac event (MACE) rate was 0% in both groups ( P =NS). No stent thromboses were reported at 1, 6, 9, or 12 months. At 12 months, the MACE rate was 3% (1 event) in the TAXUS group and 10% (4 events in 3 patients) in the control group ( P =NS). Six-month angiographic restenosis rates were 0% for TAXUS versus 10% for control ( P =NS) patients. There were significant improvements in minimal lumen diameter (2.60±0.49 versus 2.19±0.65 mm), diameter stenosis (13.56±11.77 versus 27.23±16.69), and late lumen loss (0.36±0.48 versus 0.71±0.48 mm) in the TAXUS group (all P <0.01). No evidence of edge restenosis was seen in either group. Intravascular ultrasound analysis showed significant improvements in normalized neointimal hyperplasia in the TAXUS (14.8 mm 3 ) group compared with the control group (21.6 mm 3 ) ( P <0.05). Conclusions— In this feasibility trial, the TAXUS slow-release stent was well tolerated and showed promise for treatment of coronary lesions, with significant reductions in angiographic and intravascular ultrasound measures of restenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3