Sensitivity of end-systolic pressure-dimension and pressure-volume relations to the inotropic state in humans.

Author:

Borow K M,Neumann A,Wynne J

Abstract

The value for the slope of the left ventricular (LV) end-systolic pressure-dimension and pressure-volume relations has been proposed as a quantitative measure of the LV inotropic state. This measure of LV inotropic state is attractive because it is independent of preload and incorporates afterload. To investigate the sensitivity of the slope of these relations to alterations in contractile state, 10 normal subjects were studied using M-mode echocardiographic, phonocardiographic and indirect carotid pulse recordings during infusion of methoxamine to alter end-systolic pressure and during infusion of dobutamine (5 micrograms/kg/min) to increase LV inotropic state. Heart rate was maintained within a narrow range for each subject. End-systolic volume was calculated from end-systolic echocardiographic dimension by standard methods. End-systolic pressure was estimated from the dicrotic notch pressure determined from a calibrated carotid pulse recording; peak systolic pressure was also measured. Regardless of the method of approximating end-systolic pressure, the positive inotropic intervention caused a leftward shift in the end-systolic pressure-dimension and pressure-volume lines. With the dobutamine infusion, the value for the slope of the end-systolic pressure-dimension relation increased by 25% (range 16-46%, p less than 0.001), while the slope of the end-systolic pressure-volume relation increased by 55% (range 37-85%, p less than 0.001). In all cases, the curves were linear and became steeper with the positive inotropic intervention. In contrast, the value of the slope of the peak systolic pressure-end-systolic dimension relation showed a variable response to the dobutamine infusion (mean change 13%, range -77% to 73%; NS). Although the position of the peak systolic pressure-end-systolic dimension curve is consistently shifted with an alteration in inotropic state, the values of the slope of these curves are not reliable indicators of change in LV contractility. The values for the slope of the line relating end-systolic pressure (estimated by dicrotic notch pressure) to end-systolic dimension or volume, however, are highly sensitive to a change in inotropic state in human subjects.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 244 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3