Rethrombosis after reperfusion with streptokinase: importance of geometry of residual lesions.

Author:

Harrison D G,Ferguson D W,Collins S M,Skorton D J,Ericksen E E,Kioschos J M,Marcus M L,White C W

Abstract

We tested the hypothesis that lesion rethrombosis after streptokinase reperfusion is related to luminal size of the residual stenosis. Two independent techniques of analyzing coronary angiograms, quantitative coronary angiography and computer-based videodensitometry, were used to estimate the size of the residual lumen immediately after discontinuation of streptokinase. These techniques were selected because they provide independent estimates of cross-sectional area of a lesion with high degrees of reproducibility and minimal observer variability. Twenty-four patients who had undergone successful reperfusion with streptokinase were studied. Seven patients had lesion rethrombosis documented either on a repeat angiogram, at autopsy, or, in one case, by the fact that the patient had an acute transmural infarction resulting in death. Vessel patency was documented by repeat coronary angiography 8 to 14 days after initial streptokinase reperfusion in the other 17 patients. As assessed by quantitative coronary angiography, seven of 13 patients (54%) with minimal luminal cross-sectional areas of less than 0.4 mm2 had rethrombosis. None of the 11 patients with lumens greater than 0.4 mm2 had rethrombosis. In the 17 patients with vessels that remained patent the size of the residual lesion at repeat catheterization was compared with its size immediately after reperfusion with streptokinase. Over the intervening 8 to 14 day interval, an average percentage increase in minimal cross-sectional area of 116 +/- 34% was observed. In seven patients minimal luminal cross-sectional area more than doubled. Integrated optical density, an index of the severity of coronary stenosis derived from computer-based videodensitometry, was also useful in identifying a subgroup of patients at high risk for rethrombosis of lesion.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 353 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3