Author:
Wisneski J A,Pfeil C N,Wyse D G,Mitchell R,Rahimtoola S H,Gertz E W
Abstract
The ejection fraction is one of the most widely used measurements of left ventricular systolic function. Angiographic measurement of ejection fraction is based on determination of roentgenographic magnification and calculation of end-diastolic and end-systolic volumes, assuming a prolated ellipse. Because it is simple and radiographic magnification may not have been determined, some laboratories have obtained an "ejection fraction" by comparison of end-diastolic and end-systolic areas. A comparison of the two methods was made using ventriculograms of 538 patients from three cardiac catheterization laboratories. The area method of ejection fraction calculation consistently underestimates ejection fraction from left ventricular volumes. A regression equation was derived that allows adjustment of the ejection fraction obtained from areas to that from volumes.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献