Abstract
Regional myocardial function and blood flow in endocardial layers were correlated in myocardial segments subtending severely ischemic and adjacent, normally perfused myocardium in conscious dogs 1--3 weeks after recovery from coronary artery occlusion. With coronary artery occlusion induced by a hydraulic occluder, endocardial blood flow (measured with radioactive microspheres) and function (determined with an ultrasonic dimension gauge) in homogeneously nonischemic segments increased slightly but not significantly. In homogeneously ischemic segments, blood flow and function decreased (p less than 0.01) by 96 +/- 1% and 98 +/- 4%, respectively. In segments subtending zones of unequal perfusion, endocardial blood flow increased nonsignificantly in the myocardium surrounding the nonischemic crystal, while decreasing by 93 +/- 2% (p less than 0.01) in myocardium surrounding the ischemic crystal. Surprisingly, these segments behaved like homogeneously ischemic segments, i.e., endocardial shortening decreased by 92 +/- 6% (p less than 0.01). Thus, the failure to detect shortening despite normal perfusion of the myocardium surrounding one of the transducers suggest a potential problem with interpretation of regional function measurements or an inability of the apparently nonischemic myocardium to contract.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
46 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献