Novel MRI Contrast Agent for Molecular Imaging of Fibrin

Author:

Flacke Sebastian1,Fischer Stefan1,Scott Michael J.1,Fuhrhop Ralph J.1,Allen John S.1,McLean Mark1,Winter Patrick1,Sicard Gregorio A.1,Gaffney Patrick J.1,Wickline Samuel A.1,Lanza Gregory M.1

Affiliation:

1. From the Radiologische Klinik, Universität Bonn, Bonn, Germany (S. Flacke); Philips Medical Systems, Best, Netherlands (S. Fischer); the Department of Medicine, Cardiovascular Division, Washington University Medical School, St Louis, Mo (M.J.S., R.J.F., J.S.A, M.M., P.W., G.A.S., S.A.W., G.M.L.); and the Department of Surgery, St Thomas’s Hospital, London, UK (P.J.G.).

Abstract

Background Molecular imaging of thrombus within fissures of vulnerable atherosclerotic plaques requires sensitive detection of a robust thrombus-specific contrast agent. In this study, we report the development and characterization of a novel ligand-targeted paramagnetic molecular imaging agent with high avidity for fibrin and the potential to sensitively detect active vulnerable plaques. Methods and Results The nanoparticles were formulated with 2.5 to 50 mol% Gd-DTPA-BOA, which corresponds to >50 000 Gd 3+ atoms/particle. Paramagnetic nanoparticles were characterized in vitro and evaluated in vivo. In contradistinction to traditional blood-pool agents, T1 relaxation rate as a function of paramagnetic nanoparticle number was increased monotonically with Gd-DTPA concentration from 0.18 mL · s −1 · pmol −1 (10% Gd-DTPA nanoparticles) to 0.54 mL · s −1 · pmol −1 for the 40 mol% Gd-DTPA formulations. Fibrin clots targeted in vitro with paramagnetic nanoparticles presented a highly detectable, homogeneous T1-weighted contrast enhancement that improved with increasing gadolinium level (0, 2.5, and 20 mol% Gd). Higher-resolution scans and scanning electron microscopy revealed that the nanoparticles were present as a thin layer over the clot surface. In vivo contrast enhancement under open-circulation conditions was assessed in dogs. The contrast-to-noise ratio between the targeted clot (20 mol% Gd-DTPA nanoparticles) and blood was ≈118±21, and that between the targeted clot and the control clot was 131±37. Conclusions These results suggest that molecular imaging of fibrin-targeted paramagnetic nanoparticles can provide sensitive detection and localization of fibrin and may allow early, direct identification of vulnerable plaques, leading to early therapeutic decisions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 487 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3