Noninvasive Assessment of Cardiac Output: Accuracy and Precision of the Closed‐Circuit Acetylene Rebreathing Technique for Cardiac Output Measurement

Author:

Hardin E. Ashley12,Stoller Douglas12,Lawley Justin12,Howden Erin J.12,Hieda Michinari12ORCID,Pawelczyk James3,Jarvis Sara4,Prisk Kim5,Sarma Satyam12,Levine Benjamin D.12ORCID

Affiliation:

1. Division of Cardiology Department of Internal Medicine University of Texas Southwestern Medical Center Dallas TX

2. Institute for Exercise and Environmental Medicine Texas Health Presbyterian Hospital Dallas TX

3. Department of Physiology Pennsylvania State University University Park and Hershey PA

4. Department of Biological Sciences Northern Arizona University Flagstaff AZ

5. Department of Medicine University of California at San Diego La Jolla CA

Abstract

Background Accurate assessment of cardiac output is critical to the diagnosis and management of various cardiac disease states; however, clinical standards of direct Fick and thermodilution are invasive. Noninvasive alternatives, such as closed‐circuit acetylene (C 2 H 2 ) rebreathing, warrant validation. Methods and Results We analyzed 10 clinical studies and all available cardiopulmonary stress tests performed in our laboratory that included a rebreathing method and direct Fick or thermodilution. Studies included healthy individuals and patients with clinical disease. Simultaneous cardiac output measurements were obtained under normovolemic, hypovolemic, and hypervolemic conditions, along with submaximal and maximal exercise. A total of 3198 measurements in 519 patients were analyzed (mean age, 59 years; 48% women). The C 2 H 2 method was more precise than thermodilution in healthy individuals with half the typical error (TE; 0.34 L/min [ r =0.92] and coefficient of variation, 7.2%) versus thermodilution (TE=0.67 [ r =0.70] and coefficient of variation, 13.2%). In healthy individuals during supine rest and upright exercise, C 2 H 2 correlated well with thermodilution (supine: r =0.84, TE=1.02; exercise: r =0.82, TE=2.36). In patients with clinical disease during supine rest, C 2 H 2 correlated with thermodilution ( r =0.85, TE=1.43). C 2 H 2 was similar to thermodilution and nitrous oxide (N 2 O) rebreathing technique compared with Fick in healthy adults (C 2 H 2 rest: r =0.85, TE=0.84; C 2 H 2 exercise: r =0.87, TE=2.39; thermodilution rest: r =0.72, TE=1.11; thermodilution exercise: r =0.73, TE=2.87; N 2 O rest: r =0.82, TE=0.94; N 2 O exercise: r =0.84, TE=2.18). The accuracy of the C 2 H 2 and N 2 O methods was excellent ( r =0.99, TE=0.58). Conclusions The C 2 H 2 rebreathing method is more precise than, and as accurate as, the thermodilution method in a variety of patients, with accuracy similar to an N 2 O rebreathing method approved by the US Food and Drug Administration.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3