Abstract

Background This study evaluated the role of supplementing Society of Thoracic Surgeons (STS) risk models for surgical aortic valve replacement with machine learning (ML). Methods and Results Adults undergoing isolated surgical aortic valve replacement in the STS National Database between 2007 and 2017 were included. ML models for operative mortality and major morbidity were previously developed using extreme gradient boosting. Concordance and discordance in predicted risk between ML and STS models were defined using equal‐size tertile‐based thresholds of risk. Calibration metrics and discriminatory capability were compared between concordant and discordant patients. A total of 243 142 patients were included. Nearly all calibration metrics were improved in cases of concordance. Similarly, concordance indices improved substantially in cases of concordance for all models with the exception of deep sternal wound infection. The greatest improvements in concordant versus discordant cases were in renal failure: ML model (concordance index, 0.660 [95% CI, 0.632–0.687] discordant versus 0.808 [95% CI, 0.794–0.822] concordant) and STS model (concordance index, 0.573 [95% CI, 0.549–0.576] discordant versus 0.797 [95% CI, 0.782–0.811] concordant) (each P <0.001). Excluding deep sternal wound infection, the concordance indices ranged from 0.549 to 0.660 for discordant cases and 0.674 to 0.808 for concordant cases. Conclusions Supplementing ML models with existing STS models for surgical aortic valve replacement may have an important role in risk prediction and should be explored further. In particular, for the roughly 25% to 50% of patients demonstrating discordance in estimated risk between ML and STS, there appears to be a substantial decline in predictive performance suggesting vulnerability of the existing models in these patient subsets.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3