Effect of Regional and Systemic Changes in Vasomotor Tone on Finger Pressure Amplification

Author:

Bos Willem Jan W.1,van den Meiracker Anton H.1,Wesseling Karel H.1,Schalekamp Maarten A.D.H.1

Affiliation:

1. From the Department of Internal Medicine I, University Hospital Rotterdam, Dijkzigt, Rotterdam, and TNO, Biomedical Instrumentation, Academic Medical Center, Amsterdam (K.H.W.), Netherlands.

Abstract

Abstract Pulse wave amplification, which leads to increased peripheral systolic pressures, is observed during vasoconstriction after head-up tilt and during exercise. This may influence finger pressure measurements with the Finapres. To distinguish between changes in regional vascular tone and changes in systemic hemodynamics as a cause of pulse wave amplification, we measured finger pressure, intra-arterial brachial artery pressure, heart rate, and left ventricular ejection time during high-dose intravenous and low-dose intra-arterial infusions of phenylephrine and sodium nitroprusside in eight subjects. Forearm blood flow was measured by means of venous occlusion plethysmography. Intravenous phenylephrine at the highest dose caused an increase in mean brachial artery pressure of 24±3 mm Hg, a decrease in heart rate of 10±11 beats per minute, and an increase in ejection time of 23±9 milliseconds (all P <.01), whereas pulse wave amplification was reduced. Finapres underestimated the rise in systolic brachial artery pressure of 41±9 mm Hg by 11±12 mm Hg ( P <.01). Forearm blood flow did not change. Intravenous nitroprusside caused a decrease in mean brachial artery pressure of 23±9 mm Hg, an increase in heart rate of 18±11 beats per minute, and a decrease in ejection time of 36±31 milliseconds (all P <.01), whereas pulse wave amplification increased. Finapres underestimated the fall in systolic brachial artery pressure of 30±13 mm Hg by 9±10 mm Hg ( P <.05). Forearm blood flow did not change. During regional infusion of phenylephrine and nitroprusside forearm flow halved and doubled, respectively. Blood pressure levels and pulse wave amplification were not affected. One subject performed dynamic exercise, which caused an increase in blood pressure and heart rate and a decrease in ejection time. As previously observed during bicycle exercise and contrary to the results with phenylephrine, the rise in systolic brachial artery pressure was overestimated with Finapres because of increased pulse wave amplification. We conclude that changes in regional vascular tone are not the main determinant of pulse wave amplification between the brachial and finger arteries. Changes in systemic hemodynamics, in particular changes in heart rate or ejection time, rather than changes in blood pressure level appear to be most important.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3