Safety and Feasibility of Dobutamine-Atropine Stress Testing in Hypertensive Patients

Author:

Elhendy Abdou1,van Domburg Ron T.1,Roelandt Jos R. T. C.1,Geleijnse Marcel L.1,Ibrahim M. Mohsen1,Fioretti Paolo M.1

Affiliation:

1. From the Thoraxcenter, University Hospital Rotterdam-Dijkzigt, Erasmus University, Rotterdam, Netherlands.

Abstract

Abstract Dobutamine stress testing is increasingly used for the diagnosis and functional evaluation of coronary artery disease. The aim of this study was to assess the hemodynamic profile, safety, and feasibility of dobutamine stress testing in hypertensive patients. Dobutamine (up to 40 μg/kg per min-ute)–atropine (up to 1 mg) stress echocardiography was performed for the detection of myocardial ischemia in 1164 patients with limited exercise capacity (age, 60±12 years; 761 men); 446 patients were known to have hypertension. The test was considered feasible when 85% of the maximal heart rate and/or an ischemic end point (new or worsened wall motion abnormalities, ST segment depression, or angina) was achieved. No myocardial infarction or death occurred during the test. Dobutamine induced a significant increase of heart rate in patients with and without hypertension (59±25 and 63±23 beats per minute, respectively). Peak rate pressure product was similar in patients with and without hypertension (18 566±4584 and 18 230±4508). Hypotension (systolic pressure drop >40 mm Hg) during the test was more frequent in hypertensive patients (7% versus 4% in normotensive, P <.05). Independent predictors of hypotension were baseline systolic pressure greater than 140 mm Hg (odds ratio, 6.9; 95% confidence interval, 3.4 to 14), older age (odds ratio, 1.04; 95% confidence interval, 1.01 to 1.07), and medication with calcium channel blockers (odds ratio, 1.8; 95% confidence interval, 1.1 to 3.5). The prevalence of ventricular tachycardia was similar (4.1%) in both groups. Episodes of 10 beats or more (0.06% of patients) were terminated promptly by intravenous metoprolol administration. Dobutamine stress testing was considered feasible in 91% of patients with and 92% of patients without hypertension. Dobutamine-atropine stress echocardiography is a safe and feasible method for the assessment of hypertensive patients referred for evaluation of myocardial ischemia. Despite the higher prevalence of dobutamine-induced hypotension in these patients, the feasibility of the test is comparable to that in individuals without hypertension.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3