Background The use of embolic protection devices ( EPD ) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta‐analysis was to assess the safety and efficacy profile of current EPD . Methods and Results Major medical databases were searched up to December 2017 for studies that evaluated patients undergoing transcatheter aortic valve implantation with or without EPD . End points of interest were 30‐day mortality, 30‐day stroke, the total number of new lesions, the ischemic volume per lesion, and the total volume of lesions. Eight studies involving 1285 patients were included. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. The use of EPD was not associated with significant differences in terms of 30‐day mortality (odds ratio 0.43 [0.18–1.05], P =0.3) but it was associated with a lower rate of 30‐day stroke (odds ratio 0.55 [0.31–0.98], P =0.04). No differences were detected with respect to the number of new lesions (standardized mean difference −0.19 [−0.71 to 0.34], P =0.49). The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, −0.52 [−0.85 to −0.20], P =0.002) and smaller total volume of lesions (standardized mean difference, −0.23 [−0.42 to −0.03], P =0.02). Conclusions The use of EPD is not associated with a reduced rate of mortality and new ischemic cerebral lesions. The use of EPD during transcatheter aortic valve implantation seems to be associated with a lower 30‐day stroke rate, although this result is driven by a single nonrandomized study. The use of EPD is associated with a smaller volume of ischemic lesions, and smaller total volume of ischemic lesions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3