Potential of 99mTc-LDLs labeled by two different methods for scintigraphic detection of experimental atherosclerosis in rabbits.

Author:

Atsma D E1,Feitsma R I1,Camps J1,van't Hooft F M1,van der Wall E E1,Nieuwenhuizen W1,Pauwels E K1

Affiliation:

1. Gaubius Laboratory, University Hospital Leiden, The Netherlands.

Abstract

In this study we evaluated two different 99mTc-labeling techniques to produce 99mTc-low density lipoprotein (99mTc-LDL) suitable for the scintigraphic delineation of experimental atherosclerotic lesions. The two methods are 1) a procedure that uses stannous chloride and sodium borohydride (borohydride method) and 2) a procedure that uses sodium dithionite as a reducing agent and that has been successfully applied in previous scintigraphic atherosclerosis detection (dithionite method). 99mTc-LDL produced by either method was injected into New Zealand White rabbits with diet-induced atherosclerotic plaques and in control rabbits. Scintigraphic images were taken 10 minutes (t = 0) and 1, 4, 8, 16, and 24 hours after injection. Clearance of plasma radioactivity was also studied. Stability of the 99mTc-LDL complex in the circulation was examined by size exclusion chromatography of plasma samples. After scintigraphy, the animals were killed, and the biodistribution of radioactivity was determined. The thoracic and abdominal aortas appeared in scintigraphic images to accumulate 99mTc over their entire length with either 99mTc-LDL preparation. The sparse imaging of focal atherosclerosis was found to be due to the fact that the aortas were covered with confluent atherosclerotic lesions. Scintigraphic image analysis showed that 24 hours after injection, the accumulated radioactivity in the abdominal aorta of the atherosclerotic rabbits was 57% and 54%, respectively, of the accumulated radioactivity in the abdominal aorta at t = 0 when the borohydride versus the dithionite method was used. In the control animals this value was 25% for the dithionite method, whereas in the borohydride method the aortas could not be detected in the images at t = 24 hours.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3