Affiliation:
1. From the Unit for Cardiovascular Research, School of Medicine, Free University Brussels (V.U.B.), Brussels, Belgium.
Abstract
The orthogonal electrocardiogram (Frank leads) is a reasonable compromise between the demands of practicability and diagnostic accuracy. The accuracy has been enhanced by the use of computerized multivariate statistical procedures. The work of the last two or three decades, however, has shown that these leads account for only part of the total available surface information. In this paper, the missing waveform information with respect to the Frank leads is quantitatively and systematically determined and a method of retrieval is worked out.
The essence of this method rests on the empirical evidence obtained by testing each of the 126 surface electrocardiograms for the XYZ content. The results are analyzed by a least squares, best fit procedure. The poorly fitted curves are considered as additional waveform sources. The number and the sites of the additional information are determined on a test group of 207 patients. The "total" surface waveform information is found to be represented by nine surface leads. This set of waveforms is then tested on a control group consisting of 205 patients. An average resynthesis coefficient of 96% is reached. No further resynthesis is looked for because of the estimated noise level.
Although the waveforms recorded at these sites represent the minimum number of unique building blocks capable of synthesizing any waveform on the body surface, they cannot predict the surface potential distribution at all surface points. This information is "total" as far as statistical procedures-performing discriminant analysis on time-functions—are concerned. This "total" waveform information consists of a set of electrocardiograms recorded in each individual at nine well-defined anatomical locations.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference29 articles.
1. Correlation of clinical information in the standard 12-lead ECG and in a corrected orthogonal 3-lead ECG
2. Diagnostic accuracy of the vectorcardiogram and electrocardiogram
3. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@70052b87
: Computer analysis of the electrocardiogram. Computers in Biomedical Research. Vol.
4. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@31facbe4 Inc. 1965 p 337
Cited by
42 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Computer Analysis of the Electrocardiogram;Specialized Aspects of ECG;2011-09-27
2. Lead Systems;Basic Electrocardiology;2011-09-22
3. The Coming of Age of Electrocardiology;Basic Electrocardiology;2011-09-22
4. Computer Analysis of the Electrocardiogram;Comprehensive Electrocardiology;2010
5. Lead Systems;Comprehensive Electrocardiology;2010