The Missing Waveform Information in the Orthogonal Electrocardiogram (Frank Leads)

Author:

KORNREICH F.1

Affiliation:

1. From the Unit for Cardiovascular Research, School of Medicine, Free University Brussels (V.U.B.), Brussels, Belgium.

Abstract

The orthogonal electrocardiogram (Frank leads) is a reasonable compromise between the demands of practicability and diagnostic accuracy. The accuracy has been enhanced by the use of computerized multivariate statistical procedures. The work of the last two or three decades, however, has shown that these leads account for only part of the total available surface information. In this paper, the missing waveform information with respect to the Frank leads is quantitatively and systematically determined and a method of retrieval is worked out. The essence of this method rests on the empirical evidence obtained by testing each of the 126 surface electrocardiograms for the XYZ content. The results are analyzed by a least squares, best fit procedure. The poorly fitted curves are considered as additional waveform sources. The number and the sites of the additional information are determined on a test group of 207 patients. The "total" surface waveform information is found to be represented by nine surface leads. This set of waveforms is then tested on a control group consisting of 205 patients. An average resynthesis coefficient of 96% is reached. No further resynthesis is looked for because of the estimated noise level. Although the waveforms recorded at these sites represent the minimum number of unique building blocks capable of synthesizing any waveform on the body surface, they cannot predict the surface potential distribution at all surface points. This information is "total" as far as statistical procedures-performing discriminant analysis on time-functions—are concerned. This "total" waveform information consists of a set of electrocardiograms recorded in each individual at nine well-defined anatomical locations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference29 articles.

1. Correlation of clinical information in the standard 12-lead ECG and in a corrected orthogonal 3-lead ECG

2. Diagnostic accuracy of the vectorcardiogram and electrocardiogram

3. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@70052b87 : Computer analysis of the electrocardiogram. Computers in Biomedical Research. Vol.

4. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@31facbe4 Inc. 1965 p 337

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Computer Analysis of the Electrocardiogram;Specialized Aspects of ECG;2011-09-27

2. Lead Systems;Basic Electrocardiology;2011-09-22

3. The Coming of Age of Electrocardiology;Basic Electrocardiology;2011-09-22

4. Computer Analysis of the Electrocardiogram;Comprehensive Electrocardiology;2010

5. Lead Systems;Comprehensive Electrocardiology;2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3