Abstract
Forearm blood flow was determined at rest and during steady state grip exercise by the venous occlusion technique with a single strand mercury-in-rubber strain gauge plethysmograph and was compared with blood flow simultaneously determined by an electromagnetic flowmneter around the brachial artery before, during, and after intermittent isotonic grip exercise in eight subjects. The comparison of plethysmographic flow (
y
axis) with simultaneously measured flowmeter flow (
x
axis) yielded a correlation coefficient of 0.797, a slope of 1.15 and a
y
intercept of 9.62. When flow was normalized per 100 cc of forearm, the correlation coefficient was 0.823, the slope 1.21, and the
y
intercept 0.871. The overestimation of the flowmeter blood flow by the plethysmograph could be explained by flow through skin vessels which bypassed the flowmeter. When averaged plethysmographic flow was compared to total planimetered flowmeter flow during exercise, there was a 1.7 times overestimation by the former technique, which was constant over the range of exercise employed.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference17 articles.
1. The measurement of changes in human limb volume by means of a mercury-in-rubber strain gauge;J Physiol (London)
2. The measurement of volume changes in human limbs
3. Use of a new simplified plethysmograph in the clinical evaluation of patients with arteriosclerosis obliterans;Surg Gynecol Obstet,1961
4. Investigation of arterial obstruction using a mercury-in-rubber strain gauge