Randomized Comparison of High-Sensitivity Troponin Reporting in Undifferentiated Chest Pain Assessment

Author:

Chew Derek P.1,Zeitz Christopher1,Worthley Matthew1,Grantham Hugh1,Beltrame John1,Arstall Margaret1,Coates Penelope1,Astley Carolyn1,Quinn Stephen1,Ratcliffe Julie1,Horsfall Matthew1,Aylward Philip G.1

Affiliation:

1. From the Flinders University, Adelaide, South Australia, Australia (D.P.C., H.G., C.A., S.Q., J.R., P.G.A.); Flinders Medical Centre, Adelaide, South Australia, Australia (D.P.C., P.G.A.); University of Adelaide, Adelaide, South Australia, Australia (C.Z., M.W., J.B.); The Royal Adelaide Hospital, Adelaide, South Australia, Australia (C.Z., M.W.); The Queen Elizabeth Hospital, Adelaide South Australia, Australia (J.B.); The Lyell McEwen Hospital, Adelaide, South Australia, Australia (M.A.); SA...

Abstract

Background— High-sensitivity troponin T (hs-TnT) assays promise greater discrimination of evolving myocardial infarction, but the impact of unguided implementation on the effectiveness of care is uncertain. Methods and Results— We evaluated the impact of hs-TnT reporting on care and outcome among chest pain patients presenting to 5 emergency departments within a multicenter randomized trial. Patients were allocated to hs-TnT reporting (hs-report) or standard reporting (std-report; Roche Elecys). The primary end point was death and new or recurrent acute coronary syndrome by 12 months. A total of 1937 patients without ST-segment elevation were enrolled between July 2011 and March 2013. The median age was 61 (interquartile range, 48–74) years, and 46.3% were women. During the index hospitalization, 1466 patients (75.7%) had maximal troponin <30 ng/L within 24 hours. Randomization to hs-report format did not alter the admission rate (hs-report: 57.7% versus std-report: 58.0%; P =0.069). There was no difference in angiography (hs-report: 11.9% versus std-report: 10.9%; P =0.479). The hs-reporting did not reduce 12-month death or new/recurrent acute coronary syndrome in the overall population (hs-report: 9.7% versus std-report: 7.2% [hazard ratio, 0.83 (0.57–1.22); P =0.362]). However, among those with troponin levels <30 ng/L, a modest reduction in the primary end point was observed (hs-report: 2.6% versus std-report: 4.4%, [hazard ratio, 0.58; 95% confidence interval, 0.34–0.1.00; P =0.050). Conclusions— High-sensitivity troponin reporting alone is associated with only modest changes in practice. Clinical effectiveness in the adoption of high-sensitivity troponin may require close coupling with protocols that guide interpretation and care. Clinical Trial Registration— URL: http://www.ANZCTR.org.au . Unique identifier: ACTRN12611000879965.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3