Effectiveness of Left Atrial Appendage Exclusion Procedures to Reduce the Risk of Stroke: A Systematic Review of the Evidence

Author:

Noelck North1,Papak Joel1,Freeman Michele1,Paynter Robin1,Low Allison1,Motu’apuaka Makalapua1,Kondo Karli1,Kansagara Devan1

Affiliation:

1. From the Department of Medicine, VA Portland Healthcare System, Portland, OR (N.N., J.P., D.K.); Department of Medicine, Oregon Health and Science University, Portland (N.N., J.P., D.K.); and VA Evidence-based Synthesis Program, VA Portland Healthcare System, Portland, OR (M.F., R.P., A.L., M.M., K.K., D.K.).

Abstract

Background— Atrial fibrillation is an important cause of cardioembolic stroke. Oral anticoagulants (OAC) reduce stroke risk but increase the risk of serious bleeding. Left atrial appendage (LAA) procedures have been developed to isolate the LAA from circulating blood flow, as an alternative to OAC. We conducted a systematic review of the benefits and harms of surgical and percutaneous LAA exclusion procedures. Methods and Results— We searched multiple data sources, including Ovid MEDLINE, Cochrane, and Embase, through January 7, 2015. Of 2567 citations, 20 primary studies met prespecified inclusion criteria. We abstracted data on patient characteristics, stroke, mortality, and adverse effects. We assessed study quality and graded the strength of evidence using published criteria. Trials found low-strength evidence that percutaneous LAA exclusion confers similar risks of stroke and mortality as continued OAC, but this evidence was limited to the Watchman device in patients eligible for long-term OAC. Observational studies found moderate-strength evidence of serious harms with a variety of percutaneous LAA procedures. There is low-strength evidence that surgical LAA exclusion does not add significant harm during heart surgery for another indication, but evidence on stroke reduction is insufficient. Conclusions— There is limited evidence that the Watchman device may be noninferior to long-term OAC in selected patients. Data on effectiveness of LAA exclusion devices is lacking in patients ineligible for long-term OAC. Percutaneous LAA devices are associated with high rates of procedure-related harms. Although surgical LAA exclusion during heart surgery does not seem to add incremental harm, there is insufficient evidence of benefit.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Reference46 articles.

1. 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: Executive Summary

2. Cardioembolic Stroke: Clinical Features, Specific Cardiac Disorders and Prognosis

3. Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation

4. Cardioversion from Atrial Fibrillation without Prolonged Anticoagulation with Use of Transesophageal Echocardiography to Exclude the Presence of Atrial Thrombi

5. Kansagara D Noelck N Papak J Freeman M Low A Motu’apuaka M Kondo K Paynter R. The effectiveness of procedures to remove or occlude the left atrial appendage. Prospero 2015:Crd42015016685 . http://www.Crd.York.Ac.Uk/prospero/display_record.Asp?Id=crd42015016685. Accessed May 31 2016.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3