The Incidence and Long-Term Clinical Outcome of Iatrogenic Atrial Septal Defects Secondary to Transseptal Catheterization With a 12F Transseptal Sheath

Author:

Singh Sheldon M.1,Douglas Pamela S.1,Reddy Vivek Y.1

Affiliation:

1. From the Cardiac Arrhythmia Service (S.M.S., V.Y.R.), Mount Sinai School of Medicine, New York, NY; and Duke Clinical Research Institute (P.S.D.), Durham, NC.

Abstract

Background— Studies assessing the presence of a residual iatrogenic atrial septal defect (iASD) after transseptal catheterization with 8F transseptal sheaths have suggested that the majority of these iASDs close within 6 months. However, these studies have been limited by small patient numbers and short follow-up. Additionally, there are a number of novel catheter procedures in interventional cardiology and electrophysiology that use larger transseptal sheaths. The objective of this study was to assess the incidence of and complications associated with iASDs in a large cohort of patients undergoing transseptal catheterization with a 12F transseptal sheath. Methods and Results— Patients (n=253) without a preexisting interatrial shunt undergoing WATCHMAN implantation as part of the PROTECT AF study were included in this current study. Patients underwent transesophageal echocardiography with echo-contrast immediately after the procedure and at 45 days and 6 months and 12 months. Eighty-seven percent of patients had an iASD immediately after the procedure, the majority of which sealed by 6 months (incidence of iASD, 34% at 45 days, 11% at 6 months, 7% at 12 months). Whereas the majority of iASDs were >3 mm in diameter immediately after the procedure, the minority of iASD were >3 mm during the follow-up period. Additionally, interatrial shunting was predominantly left-to-right when an iASD was present. There was no significant difference in the rate of stroke and/or systemic embolism during the follow-up period in patients with or without iASD. Conclusions— Transseptal catheterization procedures with a large-diameter transseptal sheath have a high spontaneous closure rate of iASDs that is not associated with an increased rate of stroke/systemic embolization during long-term follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 72 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3