Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches

Author:

LoCoco Sarah1ORCID,Kashou Anthony H.2ORCID,Deshmukh Abhishek J.2ORCID,Asirvatham Samuel J.2ORCID,DeSimone Christopher V.2ORCID,Mikhova Krasimira M.1,Sodhi Sandeep S.1ORCID,Cuculich Phillip S.1,Ghadban Rugheed1ORCID,Cooper Daniel H.1,Maddox Thomas M.1ORCID,Noseworthy Peter A.2ORCID,May Adam M.1ORCID

Affiliation:

1. Department of Medicine, Division of Cardiovascular Diseases, Washington University School of Medicine in St. Louis, MO (S.L.C., K.M.M., S.S.S., P.S.C., R.G., D.H.C., T.M.M., A.M.M.).

2. Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (A.H.K., A.J.D., S.J.A., C.V.D., P.A.N.).

Abstract

BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3