Prospective Randomized Evaluation of High Power During CLOSE-Guided Pulmonary Vein Isolation

Author:

Wielandts Jean-Yves1ORCID,Kyriakopoulou Maria1,Almorad Alexandre1,Hilfiker Gabriela1,Strisciuglio Teresa1ORCID,Phlips Thomas1,El Haddad Milad1ORCID,Lycke Michelle1,Unger Philippe2ORCID,Le Polain de Waroux Jean-Benoît13,Vandekerckhove Yves1,Tavernier Rene1,Duytschaever Mattias14ORCID,Knecht Sebastien1ORCID

Affiliation:

1. Department of Cardiology, AZ Sint-Jan Hospital, Bruges (J.-Y.W., M.K., A.A., G.H., T.S., T.P., M.E.H., M.L., J.-B.L.P.d.W., Y.V., R.T., M.D., S.K.).

2. Department of Cardiology, CHU Saint-Pierre, Université Libre de Bruxelles, Brussels (P.U.).

3. Department of Cardiology, Cliniques Universitaires Saint-Luc, Brussels (J.-B.L.P.d.W.).

4. Department of Internal Medicine, Ghent University, Ghent, Belgium (M.D.).

Abstract

Background: CLOSE-guided atrial fibrillation (AF) ablation is based on contiguous (intertag distance ≤6 mm), optimized (Ablation Index >550 anteriorly and >400 posteriorly) point-by-point radiofrequency lesions. The optimal radiofrequency power remains unknown. Methods: The POWER-AF study is a prospective, randomized controlled monocentric study including patients with paroxysmal AF, planned for first CLOSE-guided pulmonary vein isolation using a contact force radiofrequency catheter (Thermocool SmartTouch, Biosense Webster, Inc, Irvine, CA). A total of 100 patients were randomized into 2 groups (1:1). The control group received AF ablation using the standard CLOSE protocol (35 W), whereas in the experimental group, pulmonary vein isolation was performed using high power (45 W). Endoscopic evaluation was performed in patients with intraesophageal temperature rise >38.5 °C. Results: The resulting sample size was 96 (48+48) patients. In the high power group, shorter procedure time (80 versus 102 minutes, P <0.001), shorter total radiofrequency application time (16 versus 26 minutes, P <0.001), and radiofrequency time per application (26 versus 37 s anteriorly, P <0.001 and 13 versus 17 s posteriorly, P <0.001) were observed. Endoscopic evaluation (performed in 19/48 versus 25/48 patients respectively, P =0.31) showed an ulcerative perforation in a high power group patient (treated by endoscopic stenting and normalization after ≈4 months) and a superficial ulcerative lesion in a control group patient (conservative treatment). Both occurred following excessive Ablation Index applications (up to 460 and 480, respectively) with excessive contact force (30 g on average, with peaks up to 50 g). Six-months AF recurrence was not significantly different (10% in high power versus 8% in control, P =0.74). Conclusions: This randomized controlled study shows that a 45 W radiofrequency power CLOSE protocol in patients with paroxysmal AF significantly increases the global procedural efficiency with similar midterm efficacy. However, our study showed a narrower safety margin and a limited increased efficiency at the posterior wall using high power. This advocates against the use of high power in the region neighboring the esophagus.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference32 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370