Background— The Lead Integrity Alert (LIA) was developed for Medtronic implantable cardioverter defibrillators to reduce inappropriate shocks for rapid oversensing caused by conductor fractures and reported for Medtronic Fidelis conductor fractures. The goal of this study was to compare the performance of LIA with conventional impedance monitoring for identifying lead system events (LSEs) and lead failures (LFs) in lead families that differ from Fidelis. Methods and Results— We analyzed data from 12 793 LIA enabled implantable cardioverter-defibrillator and lead combinations including 6123 St. Jude Riata or Durata, 5114 Boston Scientific Endotak, and 1556 Fidelis combinations followed in the CareLink remote monitoring network for LSEs and LFs. Each alert was adjudicated based on implantable cardioverter-defibrillator stored electrograms/diagnostics and clinical data as an LSE or non–lead system event by 2 physicians after reviewing the electrograms and clinical data. During 13 562 patient-years of LIA follow-up, there were 179 adjudicated alerts, of which 84 were LSEs (including 65 LFs) and 95 were non–lead system events. LIA identified >66% more LSE and >67% more LF compared with conventional impedance monitoring and did not differ by lead family for LSE ( P =0.573) or LF ( P =0.332). Isolated spikes on electrogram were associated more often with LF in St. Jude leads (71%) compared with Endotak (9%; P <0.001) and Fidelis leads (11%; P <0.001). The non–lead system event detection rate was different among lead families ( P <0.001) ranging from 1 in every 78.5 years (Endotak), 228.9 years (St. Jude leads), and 627.6 years (Fidelis). Conclusions— LIA markedly increased the detection rate of LSE compared with conventional impedance monitoring.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3