Temporal Association Between Atrial Fibrillation Burden in Cardiac Implantable Electronic Devices and the Risk of Heart Failure Hospitalization

Author:

Ahluwalia Nikhil1ORCID,Koehler Jodi2,Sarkar Shantanu2ORCID,Vasudevan Neethu2ORCID,Majumder Shubha2ORCID,Landman Sean R.2ORCID,Schilling Richard J.1

Affiliation:

1. St Bartholomew’s Hospital, Barts Health NHS Trust, London, United Kingdom (N.A., R.J.S.).

2. Medtronic Inc, Mounds View, MN (J.K., S.S., N.V., S.M., S.R.L.).

Abstract

BACKGROUND: Atrial fibrillation (AF) events in cardiac implantable electronic devices (CIEDs) are temporally associated with stroke risk. This study explores temporal differences in AF burden associated with HF hospitalization risk in patients with CIEDs. METHODS: Patients with HF events from the Optum de-identified Electronic Health Records from 2007 to 2021 and 120 days of preceding CIED-derived rhythm data from a linked manufacturer’s data warehouse were included. AF burden ≥5.5 h/d was defined as an AF event. The AF event burden in the case period (days 1–30 immediately before the HF event) was considered temporally associated with the HF event and compared with the AF event burden in a temporally dissociated control period (days 91–120 before the HF event). The odds ratio for temporally associated HF events and the odds ratio associated with poorly rate-controlled AF (>110 bpm) were calculated. RESULTS: In total, 7257 HF events with prerequisite CIED data were included; 957 (13.2%) patients had AF events recorded only in either their case (763 [10.5%]) or control (194 [2.7%]) periods, but not both. The odds ratio for a temporally associated HF event was 3.93 (95% CI, 3.36–4.60). This was greater for an HF event with a longer stay of >3 days (odds ratio, 4.51 [95% CI, 3.57–5.68]). In patients with AF during both the control and case periods, poor AF rate control during the case period also increased HF event risk (1.78 [95% CI, 1.22–2.61]). In all, 222 of 4759 (5%) patients without AF events before their HF event had an AF event in the 10 days following. CONCLUSIONS: In a large real-world population of patients with CIED devices, AF burden was associated with HF hospitalization risk in the subsequent 30 days. The risk is increased with AF and an uncontrolled ventricular rate. Our findings support AF monitoring in CIED algorithms to prevent HF admissions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3