Abstract

Background— Lack of an irrigated-tip magnetic catheter has limited the role of remote-controlled magnetic navigation (Niobe II, Stereotaxis) for catheter ablation of atrial fibrillation (AF). Methods and Results— A novel 3.5-mm-tip irrigated magnetic catheter (group 1, Thermocool Navistar RMT, Biosense Webster) was used for 3D left atrial reconstruction (CARTO RMT) and remote-controlled magnetic pulmonary vein isolation. A redesigned catheter was used in group 2. The primary end point was wide area circumferential pulmonary vein isolation confirmed by spiral catheter recording during ablation; secondary end points included procedural data, complications, and AF recurrence. Fifty-six consecutive patients [group 1: 28 patients, 22 males, age 64 (38 to 78) years, left atrium: 47 (34 to 52) mm; paroxysmal AF: n=21, persistent AF: n=7; group 2: 28 patients, 20 males, age 60 (24 to 78) years, left atrium: 40 (35 to 53) mm; paroxysmal AF: n=18, persistent AF: n=10] were included. The primary end point was achieved in a total of 52 of 56 (93%) patients. Median procedure duration was 315 (125 to 550) minutes (group 1: 370 [230 to 550] minutes; group 2: 243 [125 to 450] minutes). Median fluoroscopy exposure to the investigator was reduced by 31%. Tip charring in 17 of 28 (61%) and complications in 3 of 28 (11%) patients in group 1 resulted in a catheter redesign. Sinus rhythm was maintained by 35 of 50 (70%) patients during a median follow-up period of 545 (100 to 683) days. Conclusions— Remote-controlled magnetic AF ablation with real-time verification of pulmonary vein isolation is feasible with a comparable success rate to manual ablation. Safety improved after a redesign of the catheter.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3