Multiple Autonomic and Repolarization Investigation of Sudden Cardiac Death in Dilated Cardiomyopathy and Controls

Author:

Pezawas Thomas1,Diedrich André1,Winker Robert1,Robertson David1,Richter Bernhard1,Wang Li1,Byrne Daniel W.1,Schmidinger Herwig1

Affiliation:

1. From the Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria (T.P., B.R., H.S.); Departments of Medicine (A.D.), and Departments of Medicine, Pharmacology, Neurology (D.R.), Division of Clinical Pharmacology, Vanderbilt Autonomic Dysfunction Center, Vanderbilt University School of Medicine, Nashville, TN; Health and Prevention Center, Sanatorium Hera, Vienna, Austria (R.W.); and Department of Biostatistics, Vanderbilt University School of...

Abstract

Background— Prophylactic defibrillator implantation is recommended in dilated, nonischemic heart disease and left ventricular ejection fraction of ≤0.30 to 0.35. Noninvasive testing should improve accuracy in decision making of prophylactic defibrillator implantation. Methods and Results— We enrolled 60 patients (median age, 57 years) with dilated cardiomyopathy and left ventricular ejection fraction ≤0.50, and 30 control subjects (median age, 59 years) with left ventricular ejection fraction >0.50. The protocol included an initial assessment, a second assessment after 3 years, and a final follow-up: pharmacological baroreflex testing (baroreceptor reflex sensitivity), short-term spectral analysis of heart rate variability (low frequency/high frequency), and long-term time domain analysis (SD of all normal-to-normal R–R intervals), exercise microvolt T wave alternans, and signal-averaged ECG, and corrected QT-time. The median follow-up was 7 years. End points were cardiac death, resuscitated cardiac arrest, and arrhythmic death. Cardiac death was observed in 21 patients. Resuscitated cardiac arrest and arrhythmic death caused by ventricular tachyarrhythmias ≥240 per minute was observed in 7 and 10 patients, respectively. In the single time point analysis, microvolt T wave alternans, baroreceptor reflex sensitivity, and SD of all normal-to-normal R–R intervals at initial testing added significant information regarding cardiac death. Microvolt T wave alternans added information on resuscitated cardiac arrest or arrhythmic death at multiple time points ( P <0.001). False-negative microvolt T wave alternans results were seen in 8% of patients. Conclusions— Noninvasive testing and left ventricular ejection fraction could not reliably identify patients with dilated cardiomyopathy at risk of fatal ventricular tachyarrhythmias. Therefore, the strategy to confine prophylactic implantable cardioverter-defibrillator implantation to patients with dilated cardiomyopathy and severely reduced LV function should be reconsidered.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3