Impact of Median Sternotomy on Safety and Efficacy of the Subcutaneous Implantable Cardioverter Defibrillator

Author:

Sugrue Alan1ORCID,Ibrahim Rand2,Lu Marvin2ORCID,Bhatia Neal K.2,Alkukhun Laith3ORCID,Adewumi Joseph4,Schaller Robert D.1,Marchlinski Francis E.1ORCID,D’Souza Benjamin1,Nazer Babak13ORCID,Tzou Wendy4ORCID,Merchant Faisal M.2ORCID,Frankel David S.1ORCID

Affiliation:

1. Division of Cardiovascular Medicine, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia (A.S., R.D.S., F.E.M., B.D., B.N., D.S.F.).

2. Section of Cardiac Electrophysiology, Emory University School of Medicine, Atlanta, GA (R.I., M.L., N.K.B., F.M.M.).

3. Knight Cardiovascular Institute, Oregon Health and Science University, Portland (L.A., B.N.).

4. Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, University of Colorado Anschutz Medical Campus, Aurora (J.A., W.T.).

Abstract

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are an attractive alternative to transvenous ICDs among those not requiring pacing. However, the risks of damage to the S-ICD electrode during sternotomy and adverse interactions with sternal wires remain unclear. We sought to determine the rates of damage to the S-ICD lead during sternotomy, inappropriate shocks from electrical noise due to interaction with sternal wires, and failure to terminate spontaneous or induced ventricular arrhythmias. METHODS: Retrospective, multicenter study of patients undergoing sternotomy before or after S-ICD implantation. Clinical, procedural, and device-related data were collected by each center and analyzed by the coordinating center. These data were compared with a historical control cohort of nonsternotomy patients. RESULTS: Of 196 identified patients (52±16 years, 47 women), 166 underwent S-ICD implantation after sternotomy and 30 sternotomy after S-ICD. There was no damage to any lead among those who underwent sternotomy after S-ICD. Defibrillation threshold testing was performed in 63% at implant, with 91% first shock success. During a median follow-up of 29 months (range, 1–188), S-ICD first shocks successfully terminated spontaneous ventricular arrhythmias in 31 of 32 patients (97%). Inappropriate shocks occurred in 22 patients, most commonly related to T wave oversensing (n=14). Compared with the nonsternotomy controls, there were no differences in rates of first shock success for induced or spontaneous arrhythmias or rate of inappropriate shocks. CONCLUSIONS: Sternotomy before or after S-ICD does not confer additional risk relative to a historical control group without sternotomy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3