Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study

Author:

Su Lan12,Wang Songjie12,Wu Shengjie12,Xu Lei12,Huang Zhouqing12,Chen Xiao12,Zheng Rujie12,Jiang Limeng12,Ellenbogen Kenneth A.3ORCID,Whinnett Zachary I.4ORCID,Huang Weijian12ORCID

Affiliation:

1. Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, China (L.S., S. Wang, S. Wu, L.X., Z.H., X.C., R.Z., L.J., W.H.).

2. The Key Lab of Cardiovascular Disease, Science and Technology of Wenzhou, China (L.S., S. Wang, S. Wu, L.X., Z.H., X.C., R.Z., L.J., W.H.).

3. Department of Cardiology, Virginia Commonwealth School of Medicine, Richmond (K.A.E.).

4. National Heart and Lung Institute, Imperial College London, United Kingdom (Z.I.W.).

Abstract

Background: Left bundle branch pacing (LBBP) is a novel pacing method and has been observed to have low and stable pacing thresholds in prior small short-term studies. The objective of this study was to evaluate the feasibility and safety of LBBP in a large consecutive diverse group of patients with long-term follow-up. Methods: This study prospectively enrolled 632 consecutive pacemaker patients with attempted LBBP from April 2017 to July 2019. Pacing parameters, complications, ECG, and echocardiographic measurements were assessed at implant and during follow-up of 1, 6, 12, and 24 months. Results: LBBP was successful in 618/632 (97.8%) patients according to strict criteria for LBB capture. Mean follow-up time was 18.6±6.7 months. Two hundred thirty-one patients had follow-up over 2 years. LBB capture threshold at implant was 0.65±0.27 mV at 0.5 ms and 0.69±0.24 mV at 0.5 ms at 2-year follow-up. A significant decrease in QRS duration was observed in patients with left bundle branch block (167.22±18.99 versus 124.02±24.15 ms, P <0.001). Postimplantation left ventricular ejection fraction improved in patients with QRS≥120 ms (48.82±17.78% versus 58.12±13.04%, P <0.001). The number of patients with moderate and severe tricuspid regurgitation decreased at 1 year. Permanent right bundle branch injury occurred in 55 (8.9%) patients. LBB capture threshold increased to >3 V or loss of bundle capture in 6 patients (1%), 2 patients of them had a loss of conduction system capture. Two patients required lead revision due to dislodgement. Conclusions: This large observational study suggests that LBBP is feasible with high success rates and low complication rates during long-term follow-up. Therefore, LBBP appears to be a reliable method for physiological pacing for patients with either a bradycardia or heart failure pacing indication.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3