Left Bundle Branch Pacing Postatrioventricular Junction Ablation for Atrial Fibrillation: Propensity Score Matching With His Bundle Pacing

Author:

Cai Mengxing12,Wu Shengjie12,Wang Songjie12,Zheng Rujie12,Jiang Limeng12,Lian Liyou12,He Yanlei12,Zhu Ling12,Xu Lei12,Ellenbogen Kenneth A.3ORCID,Whinnett Zachary I.4ORCID,Su Lan12,Huang Weijian12ORCID

Affiliation:

1. Department of Cardiology, The First Affiliated Hospital of Wenzhou Medical University (M.C., S. Wu, S. Wang, R.Z., L.J., L.L., Y.H., L.Z., L.X., L.S., W.H.).

2. The Key Laboratory of Cardiovascular Disease of Wenzhou, China (M.C., S. Wu, S. Wang, R. Zheng, L. Jiang, L. Lian, Y. He, L. Zhu, L. Xu, L.S., W.H.).

3. Department of Cardiology, Virginia Commonwealth School of Medicine, Richmond (K.A.E.).

4. National Heart and Lung Institute, Imperial College London, United Kingdom (Z.I.W.).

Abstract

Background: Left bundle branch pacing (LBBP) has emerged as a promising pacing modality to preserve physiological left ventricular activation; however, prospective data evaluating its long-term safety and efficacy in pacemaker-dependent patients following atrioventricular junction (AVJ) ablation are lacking. This study aimed to examine the feasibility, safety, and efficacy of LBBP in patients with atrial fibrillation and heart failure (HF) after AVJ ablation and compare LBBP with His bundle pacing (HBP) through a propensity score (PS) matching analysis. Methods: We prospectively enrolled patients with atrial fibrillation and HF referred for AVJ ablation and LBBP between July 2017 and December 2019. The control group was patients selected from HBP implants performed from 2012 to 2019 using PS matching with a 1:1 ratio. Results: A total of 99 patients were enrolled in the study. The LBBP implant success rate was 100%. Left ventricular ejection fraction improved from baseline 30.3±4.9 to 1-year 47.3±14.5 in HF patients with reduced ejection fraction and from baseline 56.3±12.1 to 1-year 62.3±9.1 in HF patients with preserved ejection fraction (both P <0.001), and left ventricular ejection fraction in both groups remained stable for up to 3 years of follow-up. A threshold increase >2 V at 0.5 ms occurred in only one patient. Of 176 (81.9%) of 215 patients who received permanent HBP post-AVJ ablation, 86 were matched to the LBBP group by 1:1 PS (propensity score matched His bundle pacing, N=86; propensity score matched left bundle branch pacing, N=86). No significant differences in echocardiographic or clinical outcomes were observed between the 2 groups ( P >0.05), whereas lower thresholds, greater sensed R-wave amplitudes, and fewer complications were observed in the propensity score matched left bundle branch pacing group ( P <0.05). Conclusions: LBBP is feasible, safe, and effective in patients with atrial fibrillation and HF post-AVJ ablation and has similar clinical benefits, a higher implant success rate, better pacing parameters, and fewer complications compared with HBP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3