Mitral-Aortic Flow Reversal in Cardiac Resynchronization Therapy

Author:

Rodríguez Muñoz Daniel1,Moya Mur José Luis1,Moreno Javier1,Fernández-Golfín Covadonga1,Franco Eduardo1,Berlot Bostjan1,Monteagudo Juan Manuel1,Matía Francés Roberto1,Hernández Madrid Antonio1,Zamorano José Luis1

Affiliation:

1. From the Cardiology Department, University Hospital Ramón y Cajal, Madrid, Spain (D.R.-M., J.L.M.M., J.M., C.F.-G., E.F., B.B., J.M.M., R.M.F., A.H.M., J.L.Z.); and University of Alcalá, Madrid, Spain (A.H.M., J.L.Z.).

Abstract

Background— Flow entering the left ventricle is reversed toward the outflow tract through rotating reversal flow around the mitral valve. This was thought to facilitate early ejection, but had not been proved to date. We hypothesized that perfect coupling between reversal and ejection flow would occur at optimal atrioventricular delay (AVD), contributing to its hemodynamic superiority, and evaluated its applicability for AVD optimization. Methods and Results— Forty consecutive patients with cardiac resynchronization therapy underwent intracardiac flow analysis and AVD optimization. Reversal and ejection flow curves were studied. The presence and duration of reversal-ejection discontinuity were assessed for all programmed AVD. Reproducibility of each optimization method was evaluated through interobserver variability. Discontinuity between reversal and ejection flow was observed in all patients with longer than optimal AVD, increasing linearly with excess duration in AVD (linear R 2 =0.976, P <0.001). Longer discontinuities implied progressive decreases in pre-ejection flow velocity in the left ventricular outflow tract, with consequent loss of flow momentum. The equation optimal AVD=programmed AVD–[1.2(discontinuity duration)]+4 accurately predicted optimal AVD. Short AVD systematically compromised reversal flow because of premature ejection. Agreement over optimal AVD was superior when assessed by flow reversal method (intraclass correlation coefficient =0.931; P <0.001) over both iterative and aortic velocity–time integral methods. Conclusions— Perfect coupling between mitral-aortic flow reversal and ejection flow in the left ventricle occurs at optimal AVD. As a result, full blood momentum in the outflow tract is used to facilitate early ejection. This can be measured and provides a new method for AVD optimization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3