Efficacy and Safety of Adjunctive and Primary Use of the TightRail Mechanical Cutting Sheath for Lead Extraction

Author:

Sampognaro James R.1ORCID,Karatela Maham1,Lewis Robert K.1,Black-Maier Eric1,Pokorney Sean D.1ORCID,Hegland Donald D.1,Piccini Jonathan P.ORCID

Affiliation:

1. Cardiac Electrophysiology Section, Division of Cardiology, Duke University Medical Center & the Duke Clinical Research Institute, Durham, NC.

Abstract

Background: Rotational cutting tools are increasingly used in transvenous lead extraction. There are limited data on their safety and efficacy, particularly when used adjunctively for stalled progression. The aim of this study was to evaluate the utilization, safety, and effectiveness of mechanical rotational cutting tools for transvenous lead extraction. Methods: Patients undergoing transvenous lead extraction at a single tertiary center (April 2015 to January 2021, n=586) were included in this retrospective analysis. The study characterized the 251 patients (42.8%) whose cases involved the TightRail mechanical cutting tool. Results: Among 251 patients, 526 leads were extracted and TightRail was used for 70.5%. The TightRail was used adjunctively with the laser for 65.2% of leads, 97.8% of the time as the second tool after stalled progression. Using a multivariable logistic regression model, we found that active-fixation leads (odds ratio, 2.78 [95% CI, 1.62–4.78]; P =0.0002), dual-coil leads (odds ratio, 3.39 [95% CI, 1.87–6.16]; P<0 .0001), and lead dwell time (odds ratio, 1.16 [95% CI for 1-year increase, 1.11–1.21]; P<0 .0001) were factors independently associated with adjunctive TightRail use. Stalled progression requiring TightRail occurred most often in the innominate vein and superior vena cava (59.3%). The clinical success rate was 96.8%, and the rate of major adverse events was 2.8%. Only 1 major adverse event was observed during TightRail use. Conclusions: Rotational cutting with TightRail was used in 42.8% of transvenous lead extractions, predominantly in an adjunctive manner after stalled laser progression in the innominate vein and superior vena cava, and more frequently for dual-coil and leads with longer dwell times. Adjunctive TightRail use carries a low risk of major complications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3