Mechanism and Ablation of Arrhythmia Following Total Cavopulmonary Connection

Author:

Correa Rafael1,Sherwin Elizabeth D.1,Kovach Joshua1,Mah Douglas Y.1,Alexander Mark E.1,Cecchin Frank1,Walsh Edward P.1,Triedman John K.1,Abrams Dominic J.1

Affiliation:

1. From the Boston Children’s Hospital & Harvard Medical School, Boston, MA.

Abstract

Background— The ability to identify and ablate different arrhythmia mechanisms after the total cavopulmonary connection has not been studied in detail. Methods and Results— After obtaining Institutional Review Board approval according to institutional guidelines, consecutive patients after a total cavopulmonary connection undergoing electrophysiology study over a 6-year period were included (2006–2012). Arrhythmia mechanism was determined, and the procedural outcome was defined as complete, partial success, or failure. A 12-point arrhythmia severity score was calculated for each patient at baseline and on follow-up. Fifty-seven procedures were performed on 52 patients (18.4±11.8 years; 53.0±27.2 kg). Access to the pulmonary venous atrium was necessary in 33 procedures, via fenestration (16) or transbaffle puncture (17), and in 2 cases, an additional retrograde approach was used. In total, 80 arrhythmias were identified in 47 cases: macroreentrant (n=25) or focal atrial tachycardia (n=8), atrioventricular nodal reentry tachycardia (n=13), reentry via an accessory pathway (n=4) or via twin atrioventricular nodes (n=4), ventricular tachycardia (n=5), and undefined atrial tachycardia (n=21). Procedural outcome in 32 patients who underwent ablation was complete success (n=25), partial success (n=3), failure (n=3), or empirical ablation (n=1). After successful ablation, there was a significant decrease in arrhythmia score over 18.2 (4–32) months follow-up, with a sustained trend even in the face of arrhythmia recurrence (50%). Conclusions— Arrhythmia mechanism post total cavopulmonary connection is highly varied, encompassing simple and more complex substrates, documentation of which facilitates a strategic approach to invasive arrhythmia management. Despite the anatomic limitations, successful and clinically meaningful ablation is possible.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3