Development of a Technique for Left Ventricular Endocardial Pacing via Puncture of the Interventricular Septum

Author:

Betts Tim R.1,Gamble James H.P.1,Khiani Raj1,Bashir Yaver1,Rajappan Kim1

Affiliation:

1. From the Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, United Kingdom (T.R.B., J.H.P.G., R.K., Y.B., K.R.); and Department of Cardiology, Milton Keynes Hospital NHS Foundation Trust, Milton Keynes, United Kingdom (R.K.).

Abstract

Background— Left ventricular (LV) pacing through the coronary sinus is the standard approach for cardiac resynchronization therapy. When this route is unavailable, the alternatives have major limitations. LV endocardial pacing through the interventriuclar septum may offer a simpler solution. We describe an initial case series to demonstrate technical feasibility and to describe our refinement of the puncture technique. Methods and Results— Ten patients with previous failed coronary sinus lead implant or with nonresponse to cardiac resynchronization therapy and a suboptimal LV lead position were selected. All patients were anticoagulated. Left ventriculography and coronary angiography were performed to identify LV borders and septal vessels. Subclavian vein access was used for a superior approach ventricular transseptal puncture under fluoroscopic guidance, using a steerable sheath and a standard transseptal needle, radiofrequency needle, or radiofrequency energy delivered through a guidewire. An active-fixation pacing lead was successfully delivered to the endocardial wall of the lateral LV in all patients (9 men; age, 62±10 years). LV lead implant procedure time shortened with experience. The use of radiofrequency energy delivered through a guidewire was the most effective technique. Mean threshold and R wave at implant were 0.8±0.3 V and 10.8±3.9 mV. At follow-up (mean, 8.7 months; minimum, 0; and maximum 19), thresholds were stable, and there were no thromboembolic events. Of 9 patients, 8 were classed as clinical responders (1 had inadequate follow-up to assess response). Conclusions— LV endocardial pacing through a ventricular septal puncture is a feasible approach for cardiac resynchronization therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3