Feasibility of Combined Unipolar and Bipolar Voltage Maps to Improve Sensitivity of Endomyocardial Biopsy

Author:

Casella Michela1,Pizzamiglio Francesca1,Dello Russo Antonio1,Carbucicchio Corrado1,Al-Mohani Ghaliah1,Russo Eleonora1,Notarstefano Pasquale1,Pieroni Maurizio1,D’Amati Giulia1,Sommariva Elena1,Giovannardi Marta1,Carnevali Andrea1,Riva Stefania1,Fassini Gaetano1,Tundo Fabrizio1,Santangeli Pasquale1,Di Biase Luigi1,Bolognese Leonardo1,Natale Andrea1,Tondo Claudio1

Affiliation:

1. From the Cardiac Arrhythmia Research Centre, Milan, Italy (M.C., F.P., A.D.R., C.C., G.A.-M., E.R., S.R., G.F., F.T., C.T.); Centro Cardiologico Monzino IRCCS, Milan, Italy (E.S., M.G.); Cardiovascular and Neurological Department, San Donato Hospital, Arezzo, Italy (P.N., M.P., A.C., L.B.); Department of Experimental Medicine, Sapienza University, Rome, Italy (G.D.A.,); Texas Cardiac Arrhythmia Institute at St. David’s Medical Center, Austin (P.S., L.D.B., A.N.); Department of Cardiology, University...

Abstract

Background— Endomyocardial biopsy (EMB) has a low sensitivity. Electroanatomic voltage mapping (EVM) is effective in guiding EMB thanks to its ability in identifying and locating low-voltage regions. The analysis of unipolar EVM can correlate with epicardial pathological involvement. We evaluated the unipolar EVM in EMB areas to determine whether it can increase EMB sensitivity in diagnosing epicardial diseases. Methods and Results— We performed endocardial bipolar EVM-guided EMBs in 29 patients and we analyzed unipolar EVM at withdrawal sites. Eighty myocardial samples were collected (mean, 2.8±0.9; median, 3 fragments per patient) and 60 were suitable for histological analysis. Ten specimens (17%) were collected from an area with discordant normal bipolar/low-voltage unipolar EVM and they were diagnostic or suggestive for arrhythmogenic right ventricular dysplasia/cardiomyopathy in 6 patients, for myocarditis and sarcoidosis in 1 patient each. Six samples (10%) were collected from an area with discordant low-voltage bipolar/normal unipolar EVM and they showed nonspecific features. The sensitivity of unipolar EVMs for a diagnostic biopsy finding EMB was significantly higher compared with bipolar EVMs analyzed according to samples ( P <0.01) and patients ( P =0.008). The specificity of unipolar EMB was better than bipolar EMB when analyzed for all samples ( P =0.0014) but the difference did not reach statistical significance when analyzed by patient ( P =0.083). The diagnostic yield was 63.3% for the bipolar and 83.3% for the unipolar EVM. Conclusions— These findings suggest that use of a combined bipolar/unipolar map may be able to improve the diagnostic yield of endomyocardial ventricular biopsy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3