Impact of Physiologic Pacing Versus Right Ventricular Pacing Among Patients With Left Ventricular Ejection Fraction Greater Than 35%: A Systematic Review for the 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society

Author:

Slotwiner David J.,Raitt Merritt H.,Del-Carpio Munoz Freddy,Mulpuru Siva K.,Nasser Naseer,Peterson Pamela N.

Abstract

Background: It is unclear whether physiologic pacing by either cardiac biventricular pacing (BiVP) or His bundle pacing (HisBP) may prevent adverse structural and functional consequences known to occur among some patients who receive right ventricular pacing (RVP). Aim: Our analysis sought to review existing literature to determine if BiVP and/or HisBP might prevent adverse remodeling and be associated with structural, functional, and clinical advantages compared with RVP among patients without severe left ventricular dysfunction (>35%) who required permanent pacing because of heart block. Methods: A literature search was conducted using MEDLINE (through PubMed) and Embase to identify randomized trials and observational studies comparing the effects of BiVP or HisBP versus RVP on measurements of left ventricular dimensions, left ventricular ejection fraction (LVEF), heart failure functional classification, quality of life, 6-minute walk, hospitalizations, and mortality. Data from studies that met the appropriate population, intervention, comparator, and outcomes of interest were abstracted for meta-analysis. Studies that reported pooled outcomes among patients with LVEF both above and below 35% could not be included in the meta-analysis because of strict relationships with industry procedures that preclude retrieval of industry-retained unpublished data on the subset of patients with preserved left ventricular function. Results: Evidence from 8 studies, including a total of 679 patients meeting the prespecified criteria for inclusion, was identified. Results were compared for BiVP versus RVP, HisBP versus RVP, and BiVP+HisBP versus RVP. Among patients who received physiologic pacing with either BiVP or HisBP, the LV end-diastolic and end-systolic volumes were significantly lower (mean duration of follow-up: 1.64 years; –2.77 mL [95% CI –4.37 to –1.1 mL]; P =0.001; and –7.09 mL [95% CI –11.27 to –2.91; P =0.0009) and LVEF remained preserved or increased (mean duration of follow-up: 1.57 years; 5.328% [95% CI: 2.86%–7.8%; P <0.0001). Data on clinical impact such as functional status and quality of life were not definitive. Data on hospitalizations were unavailable. There was no effect on mortality. Several studies stratified results by LVEF and found that patients with LVEF >35% but ≤52% were more likely to receive benefit from physiologic pacing. Patients with chronic atrial fibrillation who underwent atrioventricular node ablation and pacemaker implant demonstrated clear improvement in LVEF with BiVP or HisBP versus RVP. Conclusion: Among patients with LVEF >35%, the LVEF remained preserved or increased with either BiVP or HisBP compared with RVP. However, patient-centered clinical outcome improvement appears to be limited primarily to patients who have chronic atrial fibrillation with rapid ventricular response rates and have undergone atrioventricular node ablation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3