Abstract

Background: Persistent atrial fibrillation (AF) can change to paroxysmal AF after antiarrhythmic drug medication and cardioversion. We investigated whether electrical posterior box isolation (POBI) may improve rhythm outcome of catheter ablation in those patient groups. Methods: We prospectively randomized 114 patients with persistent AF to paroxysmal AF (men, 75%; 59.8±9.9 years old) to circumferential pulmonary vein isolation (CPVI) alone group (n=57) and additional POBI group (n=57). Primary end point was AF recurrence after a single procedure, and secondary end points were recurrence pattern, cardioversion rate, and response to antiarrhythmic drugs. Results: After a mean follow-up of 23.8±10.2 months, the clinical recurrence rate did not significantly differ between the CPVI alone and additional POBI group (31.6% versus 28.1%; P =0.682; log-rank P =0.729). The recurrences as atrial tachycardias (5.3% versus 12.3%; P =0.134) and cardioversion rates (5.3% versus 10.5%; P =0.250) were not significantly different between the CPVI and POBI groups. At the final follow-up, sinus rhythm was maintained without antiarrhythmic drug in 52.6% of CPVI group and 59.6% of POBI group ( P =0.450). No significant difference was found in major complication rates between the two groups (5.3% versus 1.8%; P =0.618), but the total ablation time was significantly longer in the POBI group (4187±952 versus 5337±1517 s; P <0.001). Conclusions: In patients with persistent AF converted to paroxysmal AF by antiarrhythmic drug, the addition of POBI to CPVI did not improve the rhythm outcome of catheter ablation or influence overall safety, while leading to longer ablation time. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02176616.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3