Periaortic Ventricular Tachycardias in Nonischemic Cardiomyopathy

Author:

Nakajima Ikutaro1ORCID,Narui Ryohsuke1,Aboud Asad A.1,Adeola Oluwaseun1ORCID,McHugh Julia1,Holmes Benjamin1,Lugo Ricardo1,Richardson Travis D.1,Montgomery Jay1ORCID,Shen Sharon1,Kanagasundram Arvindh1,Michaud Gregory F.1,Stevenson William G.1ORCID

Affiliation:

1. Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, TN.

Abstract

Background: Periaortic fibrotic ventricular tachycardia (VT) substrate is common in nonischemic cardiomyopathy (NICM), often intramural, and difficult to ablate. We sought to better characterize normal and abnormal periaortic voltage map parameters and NICM periaortic VTs. Methods: In 15 patients without heart disease, the 5th percentile of endocardial voltage for increasing distance from the aortic valve ring was determined. In 53 consecutive patients with NICM (64±11 years; left ventricular ejection fraction 31±10%) undergoing ablation of recurrent VT, periaortic electrogram voltage and VT characteristics were analyzed. Results: In healthy patients, the fifth percentile of the bipolar voltage increased proportional to the distance from the aortic valve ring, from 1.0 mV at 1 cm to 1.5 mV at 1.5 cm; the corresponding unipolar voltage cutoffs were 5.0 and 7.5 mV. A total of 160 VTs were induced in 53 patients with NICM, of which 28 VTs in 20 patients had periaortic origins. Periaortic VTs were associated with similar periaortic bipolar voltage, but lower UVs consistent with intramural fibrosis as an important substrate. Periaortic VTs could be divided into left and right bundle branch block forms with mapping showing right septal and lateral exits. Left bundle branch block VTs were more often acutely abolished with ablation (100% versus 69%; P =0.034), but with a 23% incidence of heart block. Greater extent of low voltage was associated with more induced VTs and worse acute outcome. Conclusions: Adjusting voltage parameters based on distance from the aortic valve may improve definition of left ventricular outflow tract arrhythmia substrate. Periaortic VTs are common in NICM, often associated with intramural substrate and can be divided into left bundle branch block and right bundle branch block types associated with different ablation outcomes and risks.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3