Idiopathic Ventricular Arrhythmia Originating From the Cardiac Crux or Inferior Septum

Author:

Kawamura Mitsuharu1,Gerstenfeld Edward P.1,Vedantham Vasanth1,Rodrigues Derek M.1,Burkhardt J. David1,Kobayashi Youichi1,Hsia Henry H.1,Marcus Gregory M.1,Marchlinski Francis E.1,Scheinman Melvin M.1,Badhwar Nitish1

Affiliation:

1. From the Division of Cardiac Electrophysiology, University of California, San Francisco (M.K., E.P.G., V.V., H.H.H., G.M.M., M.M.S., N.B.); Overlake Medical Center, Bellevue, WA (D.M.R.); Texas Cardiac Arrhythmia Institute, Austin (J.D.B.); Division of Cardiology, Showa University School of Medicine, Tokyo, Japan (Y.K.); and Cardiovascular Division, University of Pennsylvania, Philadelphia (F.E.M.).

Abstract

Background— Idiopathic ventricular arrhythmia (VA) can arise from the epicardium near the posteroseptal region (cardiac crux). There are only 2 prior reports describing idiopathic VA from the cardiac crux. The purpose of this study was to characterize the clinical and the electrocardiographic features of idiopathic crux VA. Methods and Results— Crux VA was identified in 18 patients undergoing catheter ablation. We divided patients into 2 groups, those with VA originating from the apical crux (n=9) and the basal crux (n=9). We described the clinical and electrocardiographic characteristics of crux VA as well as the ablation results. Furthermore, we compared clinical features of crux VA with other sites of idiopathic VA. Fifteen crux VA patients (83%) had sustained ventricular tachycardia and 3 patients required implantable cardioverter defibrillator implantation because of syncope. All patients had a left superior axis and 16 patients had R>S wave in V2. In apical crux VA, all patients had a deep S wave in V6 and 8 patients (89%) had R>S wave in aVR. All apical crux patients underwent attempted ablation in the middle cardiac vein without success. In 4 of these patients, epicardial ablation with subxiphoid approach was performed successfully. All basal crux VA patients had either negative or isoelectric pattern in V1 and had R>S in V6. Patients had successful ablation within the middle cardiac vein. Conclusions— Apical versus basal crux VA is identified as a new category of idiopathic VA with distinctive electrocardiographic characteristics; ablation via the middle cardiac vein is effective for eliminating basal crux VA, whereas apical crux VA often requires a subxiphoid epicardial approach.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3