Prospective Characterization of Catheter–Tissue Contact Force at Different Anatomic Sites During Antral Pulmonary Vein Isolation

Author:

Kumar Saurabh1,Morton Joseph B.1,Lee Justin1,Halloran Karen1,Spence Steven J.1,Gorelik Alexandra1,Hepworth Graham1,Kistler Peter M.1,Kalman Jonathan M.1

Affiliation:

1. From the Department of Cardiology (S.K., J.B.M., J.L., K.H., S.J.S., J.M.K.) and Melbourne EpiCentre (A.G.), The Royal Melbourne Hospital, Parkville, Victoria, Australia; Department of Medicine (S.K., J.B.M., J.M.K.) and Statistical Consulting Centre (G.H.), University of Melbourne, Victoria, Australia; and Department of Cardiology, Alfred Hospital and Baker IDI, Prahran, Victoria, Australia (S.K., P.M.K.).

Abstract

Background— Catheter–tissue contact is critical for effective lesion creation. We characterized the contact force (CF) at different anatomic sites during antral pulmonary vein (PV) isolation for atrial fibrillation. Methods and Results— Two experienced operators performed PV isolation in 22 patients facilitated by a novel CF-sensing ablation catheter in a blinded fashion. Average CF and force-time integral data from 1602 lesions were analyzed. The left and right PV antra were divided into the following: carina, superior, inferior, anterior, and posterior quadrants for analysis. There was significant variability in CF within and between different PV quadrants ( P <0.05). Lowest CF of all left PV sites was at the carina and anterior quadrant, whereas highest CF was at the superior and inferior quadrants ( P <0.05). Lowest CF of all right PV sites was at the carina, whereas highest CF was at the anterior and inferior quadrants ( P <0.05). When comparing similar PV quadrants on the left versus right (eg, left carina versus right carina), CF was always higher in the right PVs ( P <0.05), except at the superior quadrant where CF was similar in the left and right PVs ( P =0.19). There was no specific pattern of anatomic distribution of excess CF ( P =0.39). Conclusions— Monitoring of catheter–tissue CF during PV isolation demonstrates significant variability in CF within and between different PV antral sites. Sites of lowest CF were the carina and anterior left PVs and the carina of the right PVs. This information may be important for improving ablation efficacy and clinical outcomes during PV isolation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3