Novel Electromyographic Monitoring Technique for Prevention of Right Phrenic Nerve Palsy During Cryoballoon Ablation

Author:

Franceschi Frédéric1,Koutbi Linda1,Mancini Julien1,Attarian Shahram1,Prevôt Sébastien1,Deharo Jean-Claude1

Affiliation:

1. From the Assistance Publique Hôpitaux de Marseille (APHM), Department of Cardiology (F.F., L.K., S.P., J.-C.D.) and APHM, Department of Neurology (S.A.), Timone University Hospital, Marseille, France; SESSTIM, Aix-Marseille University, INSERM, IRD and APHM, Marseille, France (J.M.); and Public Health Department, Timone University Hospital, Marseille, France (J.M.).

Abstract

Background— Right phrenic nerve palsy (PNP) is the most frequent complication of cryoballoon ablation. Diaphragmatic electromyography can predict PNP with a comfortable safety margin. Our goal was to evaluate the feasibility, efficacy, and safety of electromyography-guided PN monitoring using a novel hepatic vein approach for prevention of PNP. Methods and Results— This study includes 57 patients (47 males) indicated for cryoballoon ablation for treatment of atrial fibrillation. During right superior pulmonary vein ablation, the PN was paced at 60 beats per minute and diaphragmatic compound motor action potential (CMAP) amplitude was recorded via a quadripolar catheter positioned in a subdiaphragmatic hepatic vein. If a 30% drop in CMAP amplitude was observed, ablation was discontinued with forced deflation. Reliable recording of CMAP before ablation was feasible in 50 of 57 patients (88%). In 7 patients (12%), stable PN pacing could not be achieved. In 44 of 50 patients, CMAP amplitude remained constant during cryoapplication. The mean value of CMAP amplitude was 639.7±240.5 µV; mean variation was 13±4.3%. In 6 of 50 patients (12%) including 5 treated with a 23-mm cryoballoon and 1 with a 28-mm cryoballoon, the 30% reduction cutoff was reached and cryoablation was discontinued. Recovery of CMAP amplitude after discontinuing cryoablation took <60 seconds in all cases. No PNP or complication related to PN monitoring occurred. Conclusions— Recording of diaphragmatic CMAP using a catheter positioned in a subdiaphragmatic hepatic vein seems feasible during cryoballoon ablation. Electromyography-guided PN monitoring seems safe and potentially helpful for prevention of PNP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3