Initial Clinical Experience With a New Automated Antitachycardia Pacing Algorithm

Author:

Yee Raymond1,Fisher John D.1,Birgersdotter-Green Ulrika1,Smith Timothy W.1,Kenigsberg David N.1,Canby Robert1,Jackson Troy1,Taepke Robert1,DeGroot Paul1

Affiliation:

1. From the Department of Medicine, Division of Cardiology, Western University, London, ON, Canada (R.Y.); Department of Medicine, Montefiore-Einstein Center for Cardiovascular Disease, Montefiore Medical Center, Bronx, NY (J.D.F.); Department of Medicine, Division of Cardiology, University of California, San Diego, La Jolla (U.B.-G.); Department of Medicine, Cardiovascular Division, Washington University School of Medicine, St. Louis, MO (T.W.S.); Department of Medicine, Division of Cardiology,...

Abstract

Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the feasibility and safety of AATP in ambulatory ICD patients. Methods and Results: Enrolled patients had dual chamber or cardiac resynchronization therapy ICDs, history of ≥1 ICD-treated ventricular tachycardias (VT)/ventricular fibrillation episode, or a recorded, sustained monomorphic VT. Detection was set to ventricular fibrillation number of intervals to detect=24/32, VT number of intervals to detect≥16, and a fast VT zone of 240 to 320 ms. AATP prescribed the components and delivery of successive ATP sequences in real time, using the same settings for all patients. ICD datalogs were uploaded every ≈3 months, at unscheduled visits, exit, and death. Episodes and adverse events were adjudicated by separate committees. Results were adjusted (generalized estimating equations) for multiple episodes. AATP was downloaded into the ICDs of 144 patients (121 men), aged 67.4±11.9 years, left ventricular ejection fraction 33.1±13.6% (n=137), and treated 1626 episodes in 49 patients during 14.5±5.1 months of follow-up. Datalogs permitted adjudication of 702 episodes, including 669 sustained monomorphic VT, 20 polymorphic VT, 10 supraventricular tachycardia, and 3 malsensing episodes. AATP terminated 39 of 69 (59% adjusted) sustained monomorphic VT in the fast VT zone, 509 of 590 (85% adjusted) in the VT zone, and 6 of 10 in the ventricular fibrillation zone. No supraventricular tachycardias converted to VT or ventricular fibrillation. No anomalous AATP behavior was observed. Conclusions: The new AATP algorithm safely generated ATP sequences and controlled therapy progression in all zones without need for individualized programing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3