Trigger-Based Mechanism of the Persistence of Atrial Fibrillation and Its Impact on the Efficacy of Catheter Ablation

Author:

Inoue Koichi1,Kurotobi Toshiya1,Kimura Ryusuke1,Toyoshima Yuko1,Itoh Norihisa1,Masuda Masaharu1,Higuchi Yoshiharu1,Date Motoo1,Koyama Yasushi1,Okamura Atsunori1,Iwakura Katsuomi1,Fujii Kenshi1

Affiliation:

1. From the Cardiovascular Center (K.I., R.K., Y.T., N.I., M.M., Y.H., M.D., Y.K., A.O., K.I., K.F.), Sakurabashi Watanabe Hospital, Osaka; the Division of Arrhythmia (T.K.), Shiroyama Hospital, Habikino; and the Department of Cardiovascular Medicine (M.M.), Osaka University Graduate School of Medicine, Suita, Japan.

Abstract

Background— We investigated the possibility that a frequent trigger action might play a role in the development of persistent atrial fibrillation (PeAF) and the presence of a substrate. Methods and Results— In 263 consecutive patients who underwent catheter ablation (CA) for PeAF, electric cardioversion was performed at the beginning of the procedure to determine the presence or absence of an immediate recurrence of AF (IRAF). We defined an IRAF as a reproducible AF recurrence within 90 s after restoration of sinus rhythm by electric cardioversion. We performed a mean±SD of 1.3±0.5 sessions of CA, including pulmonary vein isolation and ablation of the premature atrial contractions that triggered the IRAF (IRAF triggers), and observed the patients for 17 (10–27) months. An IRAF was observed in 70 patients (27%), but we could not ablate the IRAF triggers in 16 (23%) of these IRAF patients. The recurrence rate of PeAF was higher in patients with an unsuccessful IRAF trigger ablation than in those with successful IRAF trigger ablation (63% versus 11%; P <0.001). A multivariable analysis also revealed that an unsuccessful IRAF trigger ablation was 1 of the independent predictors of recurrent PeAF (odds ratio, 10.9; 95% CI, 3.4–36.7). Conclusions— In the PeAF patients with an IRAF, successful elimination of the IRAF triggers, in addition to pulmonary vein isolation, resulted in a successful CA. These results imply that such triggers play a major role in the AF persistence in these PeAF patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3