Number Needed to Entrain

Author:

Maruyama Mitsunori1,Yamamoto Teppei1,Abe Junko1,Yodogawa Kenji1,Seino Yoshihiko1,Atarashi Hirotsugu1,Shimizu Wataru1

Affiliation:

1. From the Cardiovascular Center, Chiba-Hokusoh Hospital (M.M., T.Y., J.A., Y.S.) and Department of Cardiovascular Medicine (K.Y., W.S.), Nippon Medical School, Tokyo, Japan; and Tama-Nagayama Hospital & Nippon Medical School, Tokyo, Japan (H.A.).

Abstract

Background— Measuring postpacing intervals (PPIs) is the standard maneuver for localizing reentrant tachycardia circuits. However, changes or termination of the tachycardia during entrainment pacing, or difficulties in defining the correct local activity, limit the use of PPIs. Methods and Results— We hypothesized that the number of pacing stimuli needed to entrain (NNE) was useful for mapping intra-atrial reentrant tachycardias. First, 10 patients with typical atrial flutter were studied to characterize the NNE. Next, 317 entrainment attempts in 30 patients with 76 intra-atrial reentrant tachycardias were analyzed to determine the efficacy of the NNE. The NNE was small at sites within the reentrant circuit (median 2) and large at remote sites during typical atrial flutter. The NNE depended on the pacing cycle length and coupling interval of the initial paced beat, where the NNE became smaller at shorter pacing cycle lengths and coupling intervals. The NNE highly correlated with the difference between the PPI and tachycardia cycle length ( r = 0.906; P <0.001). When the pacing cycle length and coupling interval were 16 to 30 ms below the tachycardia cycle length, a NNE ≤2 and >3 predicted a PPI−tachycardia cycle length ≤20 and >20 ms, respectively, with 100% accuracy. Thirty-six (11%) entrainment attempts changed or terminated intra-atrial reentrant tachycardia. Importantly, the NNE remained valid in those cases. Furthermore, the NNE provided additional information in cases with some difficulties with PPI measurements. Conclusions— The NNE is a simple and reliable criterion, which facilitates mapping intra-atrial reentrant tachycardia. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT001747.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3