Percutaneous Hemodynamic Support With Impella 2.5 During Scar-Related Ventricular Tachycardia Ablation (PERMIT 1)

Author:

Miller Marc A.1,Dukkipati Srinivas R.1,Chinitz Jason S.1,Koruth Jacob S.1,Mittnacht Alexander J.1,Napolitano Craig1,d’Avila Andre1,Reddy Vivek Y.1

Affiliation:

1. From the Helmsley Electrophysiology Center, Mount Sinai School of Medicine, New York, NY (M.A.M., S.R.D., J.S.C., J.S.K., C.N., A.d.A., V.Y.R.); and Department of Anesthesia, Mount Sinai School of Medicine, New York, NY (A.J.M.).

Abstract

Background— Percutaneous left ventricular assist devices (pLVADs) are increasingly being used to facilitate ablation of unstable ventricular tachycardia (VT), but the safety profile and hemodynamic benefits of these devices have not been described in a systematic, prospective manner. Methods and Results— Twenty patients with scar VT underwent ablation with a pLVAD. Neuromonitoring using cerebral oximetry was performed to evaluate a cerebral desaturation threshold to guide the duration of activation/entrainment mapping. The efficacy of pLVAD support was tested in a controlled manner with simulated VT. Complete procedural success was achieved in 50% (n=8) of patients, who were initially inducible for sustained VT, and partial procedural success in 37% (n=6). Using a cerebral desaturation level of 55% as a lower safety limit to guide the duration of sustained VT, 3 patients (15%) developed mild acute kidney injury (all resolved), and 1 (5%) patient developed mild cognitive dysfunction. During fast simulated VT (300 ms), cerebral desaturation to ≤55% occurred in more than half (53%) of patients tested without pLVAD support, compared with only 5% with full pLVAD support ( P =0.003). Conclusions— In a consecutive series of patients with severe left ventricular dysfunction, pLVAD-supported scar VT ablation was safe and feasible. During fast simulated VT, a miniaturized axial flow pump imparted a more favorable hemodynamic profile compared with pharmacological agents alone. Cerebral oximetry is a complimentary monitoring modality during scar VT ablation, and avoidance of cerebral desaturations below a threshold of 55% may safely guide the duration of mapping during unstable VT.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司