Endocardial Versus Epicardial Ventricular Radiofrequency Ablation

Author:

Sacher Frederic1,Wright Matthew1,Derval Nicolas1,Denis Arnaud1,Ramoul Khaled1,Roten Laurent1,Pascale Patrizzio1,Bordachar Pierre1,Ritter Philippe1,Hocini Meleze1,Dos Santos Pierre1,Haissaguerre Michel1,Jais Pierre1

Affiliation:

1. From the University of Bordeaux, LIRYC (F.S., N.D., A.D., K.R., L.R., P.P., P.B., P.R., M.H., P.D.S., M.H., P.J.), INSERM, Centre de recherche Cardio-Thoracique de Bordeaux (F.S., N.D., A.D., P.B., P.R., M.H., P.D.S., M.H., P.J.), Bordeaux University Hospital, Bordeaux, France (F.S., N.D., A.D., K.R., L.R., P.P., P.B., P.R., M.H., P.D.S., M.H., P.J.); and St. Thomas’ Hospital & Kings College London, London, UK (M.W.).

Abstract

Background— Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF and ventricular lesion formation. We studied the impact of CF on lesion formation using an ovine model both endocardially and epicardially. Methods and Results— Twenty sheep received 160 epicardial and 160 endocardial ventricular radiofrequency applications using either a 3.5-mm irrigated-tip catheter (Thermocool, Biosense-Webster, n=160) or a 3.5 irrigated-tip catheter with CF assessment (Tacticath, Endosense, n=160), via percutaneous access. Power was delivered at 30 watts for 60 seconds, when either catheter/tissue contact was felt to be good or when CF>10 g with Tacticath. After completion of all lesions, acute dimensions were taken at pathology. Identifiable lesion formation from radiofrequency application was improved with the aid of CF information, from 78% to 98% on the endocardium ( P <0.001) and from 90% to 100% on the epicardium ( P =0.02). The mean total force was greater on the endocardium (39±18 g versus 21±14 g for the epicardium; P <0.001) mainly because of axial force. Despite the force–time integral being greater endocardially, epicardial lesions were larger (231±182 mm 3 versus 209±131 mm 3 ; P =0.02) probably because of the absence of the heat sink effect of the circulating blood and covered a greater area (41±27 mm 2 versus 29±17 mm 2 ; P =0.03) because of catheter orientation. Conclusions— In the absence of CF feedback, 22% of endocardial radiofrequency applications that are thought to have good contact did not result in lesion formation. Epicardial ablation is associated with larger lesions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3