Three-Dimensional Contrast-Enhanced Multidetector CT for Anatomic, Dynamic, and Perfusion Characterization of Abnormal Myocardium To Guide Ventricular Tachycardia Ablations

Author:

Tian Jing1,Jeudy Jean1,Smith Mark F.1,Jimenez Alejandro1,Yin Xianghua1,Bruce Patricia A.1,Lei Peng1,Turgeman Aharon1,Abbo Aharon1,Shekhar Raj1,Saba Magdi1,Shorofsky Stephen1,Dickfeld Timm1

Affiliation:

1. From the University of Maryland School of Medicine (J.T., J.J., M.F.S., A.J., X.Y., P.A.B., P.L., R.S., M.S., S.S.) and Baltimore VA Medical Center (T.D.), Baltimore, Md; and Biosense Webster Inc (A.T., A.A.), Tirat Carmel, Israel.

Abstract

Background— Advances in contrast-enhanced multidetector CT enable detailed characterization of the left ventricular myocardium. Myocardial scar and border zone (BZ), as the target of ventricular tachycardia ablations, displays abnormal anatomic, dynamic, and perfusion characteristics during first-pass CT. This study assessed how contrast-enhanced CT can predict voltage-defined scar and BZ and integrate its scar reconstructions into clinical mapping systems to guide ventricular tachycardia ablations. Methods and Results— Eleven patients with ischemic cardiomyopathy underwent contrast-enhanced CT before ventricular tachycardia ablation. Segmental anatomic (end-systolic and end-diastolic wall thickness), dynamic (wall thickening, wall motion), and perfusion (hypoenhancement) characteristics were evaluated. Receiver operating characteristic curves assessed the ability of CT to determine voltage-defined scar and BZ segments. Three-dimensional epi- and endocardial surfaces and scar borders were reconstructed, coregistered, and compared to voltages using a 17-segment model. Abnormal anatomic, dynamic, and perfusion data correlated well with abnormal (<1.5 mV) endocardial voltages ( r =0.77). Three-dimensional reconstruction integrated into the clinical mapping system (registration accuracy, 3.31±0.52 mm) allowed prediction of homogenous abnormal voltage (<1.5 mV) in 81.7% of analyzed segments and correctly displayed transmural extent and intramural scar location. CT hypoperfusion correlated best with scar and BZ areas and encompassed curative ablations in 82% cases. Conclusions— Anatomic, dynamic, and perfusion imaging using contrast-enhanced CT allows characterization of left ventricular anatomy and 3D scar and BZ substrate. Integration of reconstructed 3D data sets into clinical mapping systems supplements information of voltage mapping and may enable new image approaches for substrate-guided ventricular tachycardia ablation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3