Assessment of smooth muscle contribution to descending thoracic aortic elastic mechanics in conscious dogs.

Author:

Barra J G1,Armentano R L1,Levenson J1,Fischer E I1,Pichel R H1,Simon A1

Affiliation:

1. Research and Teaching Department, Favaloro Foundation, Buenos Aires, Argentina.

Abstract

Early investigators found contradictory evidence that vascular smooth muscle activation reduces the elastic modulus of the arterial wall under isotonic conditions but increases it under isometric conditions, concomitant with increased pulse-wave velocity. We examined the individual contributions of aortic constituents to the elastic modulus of the aortic wall to determine if isobaric analysis produces an accurate assessment of vascular smooth muscle activation. We used a modified Maxwell model assuming an incremental elastic modulus (Einc) composed of the elastic modulus of elastin fibers (EE), the elastic modulus of collagen fibers (EC) affected by the fraction of collagen fibers (fC) recruited to support wall stress, and the elastic modulus of the vascular smooth muscle (ESM) according to the following formula: Einc = EE+EC x fC+ESM.Einc was assessed in eight conscious dogs using descending thoracic aortic pressure (microtransducer) and diameter (sonomicrometry) measurements. Stress-strain relations in the control state and during activation of smooth muscle by continuous administration of phenylephrine (5 micrograms.kg-1 x min-1) were obtained by transient occlusions of the descending aorta and inferior vena cava. Results were as follows: EE was 4.99 +/- 1.58 x 10(6) dynes/cm2 (mean +/- SD), and EC was 965.8 +/- 399.8 x 10(6) dynes/cm2, assessed during the control state. Phenylephrine administration increased the theoretical pulse-wave velocity (Moens-Korteweg equation) from 5.25 +/- 1.03 m/s during the control state to 7.57 +/- 2.53 m/s (P < .005). Active muscle exhibited a unimodal stress-strain curve with a maximum stress of 0.949 +/- 0.57 x 10(6) dynes/cm2 at a corresponding strain value of 1.299 +/- 0.083. The maximum value observed corresponded, on the pressure-diameter curve of the active artery, to a pressure of 234.28 +/- 46.6 mm Hg and a diameter of 17.94 +/- 1.6 mm. The maximum ESM derived from the stress-strain relation of the active muscle was 8.345 +/- 7.56 x 10(6) dynes/cm2 at a strain value of 1.283 +/- 0.079. This point was located at 208.01 +/- 40.8 mm Hg and 17.73 +/- 1.41 mm on the active pressure-diameter curve. During activation of vascular smooth muscle, Einc decreased (P < .05) when plotted against internal pressure but increased (P < .05) when plotted against strain, over the operative range.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference47 articles.

1. Burton AC. Physiology and Biophysics of the Circulation. Chicago Ill: Year Book Medical Publishers Inc; 1972:63-75.

2. Diameter and Elasticity of the Ascending Aorta during Infusion of Noradrenaline

3. Importance of the gerontology of elastic arteries in the development of essential hypertension;Bader H;Clin Physiol Biochem.,1983

4. Effects of norepinephrine on mechanics of arteries in vitro;Cox RH;Am J Physiol.,1976

5. Influence of muscle length on series elasticity in arterial smooth muscle

Cited by 134 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3