Efficacy of Pacing Therapies for Treating Atrial Tachyarrhythmias in Patients With Ventricular Arrhythmias Receiving a Dual-Chamber Implantable Cardioverter Defibrillator

Author:

Adler Stuart W.1,Wolpert Christian1,Warman Eduardo N.1,Musley Shailesh K.1,Koehler Jodi L.1,Euler David E.1,

Affiliation:

1. From the St Paul Heart Clinic, St Paul, Minn (S.W.A.); the University of Bonn, Bonn, Germany (C.W.); and Medtronic, Inc, Minneapolis, Minn (E.N.W., S.K.M., J.L.K., D.E.E.).

Abstract

Background Although overdrive pacing for treating atrial flutter is well established, the efficacy of device-based atrial pacing for treating spontaneous atrial tachyarrhythmias in patients with implantable cardioverter defibrillators (ICD) is unknown. This study evaluated the efficacy of novel pacing therapies for treating atrial tachyarrhythmias in patients receiving a dual-chamber ICD to treat ventricular tachyarrhythmias. Methods and Results A Jewel AF ICD was implanted in 537 patients with ventricular arrhythmia who were followed for 11.4±8.2 months (74% had a documented history of atrial tachyarrhythmias). The device discriminated atrial tachycardia (AT) from atrial fibrillation (AF) on the basis of cycle length and regularity, and it used 3 different methods of overdrive atrial pacing (Ramp, Burst+, and 50-Hz burst) to treat AT episodes and one method (50-Hz burst) to treat AF episodes. Pacing successfully terminated 59% of 1500 spontaneous AT episodes in 127 patients and 30% of 880 AF episodes in 101 patients ( P <0.001). With AT and AF episodes combined, pacing efficacy was 48%. Pacing efficacy was significantly reduced at AT cycle lengths ≤220 ms and AF cycle lengths ≤160 ms ( P <0.01) The median time from pacing to AT/AF termination was 1.1 minute for the pacing successes and 96 minutes for the failures ( P <0.001). Conclusions Atrial pacing terminated 48% of AT/AF episodes in patients with a history of ventricular arrhythmias. Pacing efficacy was greater for device-classified AT than AF. Pacing efficacy was significantly influenced by tachycardia cycle length. Successful pacing significantly reduces the time required for AT/AF termination.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 86 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3