Lack of Neointimal Proliferation After Implantation of Sirolimus-Coated Stents in Human Coronary Arteries

Author:

Sousa J. Eduardo1,Costa Marco A.1,Abizaid Alexandre1,Abizaid Andrea S.1,Feres Fausto1,Pinto Ibraim M. F.1,Seixas Ana C.1,Staico Rodolfo1,Mattos Luiz A.1,Sousa Amanda G. M. R.1,Falotico Robert1,Jaeger Judith1,Popma Jeffrey J.1,Serruys Patrick W.1

Affiliation:

1. From the Institute Dante Pazzanese of Cardiology, São Paulo, Brazil (J.E.S., M.A.C., A.A., A.S.A., F.F., I.M.F.P., A.C.S., R.S., L.A.M., A.G.M.R.S.); Cordis, a Johnson & Johnson Company, Warren, NJ (R.F., J.J.); Brigham and Women’s Hospital, Boston, Mass (J.J.P.); and Thoraxcenter, Dijkzigt University Hospital, Rotterdam, the Netherlands (P.W.S.).

Abstract

Background —Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. Methods and Results —Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analyzed angiographic and 3D volumetric intravascular ultrasound data (immediately after procedure and at 4-month follow-up). Eight-month clinical follow-up was obtained for all patients. There was minimal neointimal hyperplasia in both groups (11.0±3.0% in the SR group and 10.4±3.0% in the FR group, P =NS) by ultrasound and quantitative coronary angiography (in-stent late loss, 0.09±0.3 mm [SR] and −0.02±0.3 mm [FR]; in-lesion late loss, 0.16±0.3 mm [SR] and −0.1±0.3 mm [FR]). No in-stent or edge restenosis (diameter stenosis ≥50%) was observed. No major clinical events (stent thrombosis, repeat revascularization, myocardial infarction, or death) had occurred by 8 months. Conclusions —The implantation of sirolimus-coated BX Velocity stents is feasible and safe and elicits minimal neointimal proliferation. Additional placebo-controlled trials are required to confirm these promising results.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 502 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3