Affiliation:
1. From the Departments of Medicine and Radiology, University Hospitals and Western Reserve University, Cleveland, Ohio.
Abstract
Technics for determining the cardiac output by recording the dilution curve of injected iodinated I
131
human serum albumin from precordial sites have been described. By viewing predominantly either the right or left side of the heart and by rapid delivery of the isotope, quantitation of the dilution curves for cardiac output has been possible without critical requirements for placement of the counter. In a series of 26 determinations in normal patients cardiac output values calculated from simultaneously recorded precordial curves and withdrawn arterial blood showed an average agreement within ± 8 per cent. In a smaller series of 8 determinations on patients in heart failure, an average deviation of ± 9 per cent was found.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
56 articles.
订阅此论文施引文献