Initial Clinical Experience With Ambulatory Use of an Implantable Atrial Defibrillator for Conversion of Atrial Fibrillation

Author:

Daoud Emile G.1,Timmermans Carl1,Fellows Chris1,Hoyt Robert1,Lemery Robert1,Dawson Kathy1,Ayers Gregory M.1

Affiliation:

1. From Riverside-Methodist Hospital, Columbus, Ohio (E.G.D.); Academic Hospital Maastricht, the Netherlands (C.T.); Virginia Mason Medical Center, Seattle, Wash (C.F.); Iowa Heart Institute, Des Moines, Iowa (R.H.); Rhode Island Hospital, Providence, RI (R.L.); and InControl/Guidant, Inc, Redmond, Wash/St Paul, Minn (K.D., G.M.A.).

Abstract

Background —A recent study has shown that the implantable atrial defibrillator can restore sinus rhythm in patients with recurrent atrial fibrillation when therapy was delivered under physician observation. The objective of this study was to evaluate the safety and efficacy of ambulatory use of the implantable atrial defibrillator. Methods and Results —An atrial defibrillator was implanted in 105 patients (75 men; mean age, 59±12 years) with recurrent, symptomatic, drug-refractory atrial fibrillation. After successful 3-month testing, patients could transition to ambulatory delivery of shock therapy. Patients completed questionnaires regarding shock therapy discomfort and therapy satisfaction using a 10-point visual-analog scale (1 represented “not at all,” 10 represented “extremely”) after each treated episode of atrial fibrillation. During a mean follow-up of 11.7 months, 48 of 105 patients satisfied criteria for transition and received therapy for 275 episodes of atrial fibrillation. Overall shock therapy efficacy was 90% with 1.6±1.2 shocks delivered per episode (median, 1). Patients rated shock discomfort as 5.2±2.4 for successful therapy and 4.2±2.2 for unsuccessful therapy ( P >0.05). The satisfaction score was higher for successful versus unsuccessful therapy (3.4±3.3 versus 8.7±1.3, P <0.05). There was no ventricular proarrhythmia observed throughout the course of this study. Conclusions —Ambulatory use of an implantable atrial defibrillator can safely and successfully convert most episodes of atrial fibrillation, often requiring only a single shock. Successful therapy is associated with high satisfaction and only moderate discomfort.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 54 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3