Feasibility of In Vivo Intravascular Ultrasound Tissue Characterization in the Detection of Early Vascular Transplant Rejection

Author:

Jeremias Allen1,Kolz Mathew L.1,Ikonen Tuija S.1,Gummert Jan F.1,Oshima Akio1,Hayase Motoya1,Honda Yasuhiro1,Komiyama Nobuyuki1,Berry Gerald J.1,Morris Randall E.1,Yock Paul G.1,Fitzgerald Peter J.1

Affiliation:

1. From the Division of Cardiovascular Medicine (A.J., M.L.K., A.O., M.H., Y.H., N.K., P.G.Y., P.J.F.), the Department of Cardiothoracic Surgery, Transplantation Immunology (T.S.I., J.F.G., R.E.M.), and the Department of Pathology (G.J.B.), Stanford University School of Medicine, Stanford, Calif.

Abstract

Background —Unprocessed ultrasound radiofrequency (RF) signal analysis has been shown to distinguish different tissue structures more reliably than gray-scale interpretation of conventional ultrasound images. Methods and Results —The objective of this study was to test the feasibility of in vivo intravascular ultrasound (IVUS) RF signal analysis in an animal model of allograft rejection. Six cynomolgus monkeys underwent transplantation of 3-cm aortic allograft segments distal to the renal arteries from immunologically mismatched donors. IVUS imaging with a 30-MHz system was performed 84 to 105 days after the operation. RF signals were acquired from cross sections of the recipient and the allograft aortas in real time with a digitizer at 500 MHz with 8-bit resolution. Sixty-five cross sections and 68 regions of interest (31 in host aorta and 37 in allograft) were analyzed in the adventitial layer with a total number of 8568 vectors processed. For each region of interest, a weighted-average attenuation was calculated on the basis of the attenuation and length for each individual vector. Histological examination was performed at every cross section imaged by IVUS. When the gray-scale images of conventional IVUS scored by an independent observer were compared, no distinction between adventitia of the native aorta and allograft was possible. Analysis of the average RF backscatter power also showed no significant difference (70.32±3.55 versus 70.72±3.38 dB). However, the average attenuation of allografts was significantly lower than that of the host aortas (2.64±1.38 versus 4.02±1.16 dB/mm, P <0.001). Histology demonstrated a marked adventitial inflammatory response in all allografts, with no inflammation observed in the host aortas. Conclusions —In vivo IVUS tissue characterization can be performed during routine imaging. In this model of transplant vasculopathy, RF attenuation measurements were more sensitive than visual or quantitative gray-scale analysis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3